Abstract
Abstract
Background
Various types of medical glues/adhesives/topical coagulants’ (referred to as MG hereinafter) have widespread application as surgical adhesives, and have been shown to be safe and effective for a broad range of usage, such as in hemostasis, reinforcement of intestinal anastomoses or sites of potential fluid leakage, adhesion of two surfaces, wound closure, and vascular embolization. However, inappropriate application of MG may sometimes lead to serious complications. Herein, we describe three cases of serious postoperative complications induced by a possible inappropriate use of N-butyl-2-cyanoacrylate MG (NBCA MG).
Case presentation
Three patients presented with abdominal pain (chronic pain in cases 1 and 2, and acute pain in Case 3), hematochezia (Case 2), and intestinal obstruction (Case 3). All patients had a history of abdominal surgery and intraoperative use of NBCA MG. Abdominal computed tomography and gastroenterological endoscopy revealed foreign bodies (solidified MG in cases 1 and 2) and intestinal obstruction related to a mass of residual non-absorbed MG causing an internal hernia from a dense adhesion (Case 3). All patients underwent exploratory laparotomy, which revealed duodenal perforation, colonic erosion, and an internal hernia, all of which was related to MG use. We undertook removal of the foreign bodies (cases 1 and 2), surgical closure of the site of duodenal erosion (Case 1), partial colectomy (Case 2), and partial enterectomy (Case 3).
Conclusion
Inappropriate application of MG may induce serious complications. We emphasize the importance of careful evaluation of the indications, dosage, and spraying thickness of MG in clinical practice. Serious complications caused by inappropriate application of MG should be reported to raise awareness in the surgical fraternity.
Funder
National Natural Science Foundation of China
Excellent Young Foundation of Jilin Scientific and Technological Development Program
Publisher
Springer Science and Business Media LLC
Subject
Gastroenterology,General Medicine
Reference8 articles.
1. Dimitrakakis G, Podila SR, O’Keefe PA, Kulatilake NE. Biological glue: a word of careful assessment! Interact Cardiovasc Thorac Surg. 2011;13(2):244.
2. Zhang CH. Use of absorbable hemostatic gauze with medical adhesive is effective for achieving hemostasis in presacral hemorrhage. Am J Surg. 2012;203(4):e5.
3. Shen YM, Liu YT, Chen J, Sun L. Efficacy and safety of NBCA (n-butyl-2-cyanoacrylate) medical adhesive for patch fixation in totally extraperitoneal prosthesis (TEP): a prospective, randomized, controlled trial. Eur Rev Med Pharmacol Sci. 2017;21(4):680–6.
4. Doyama H, Tominaga K, Yoshida N, Takemura K, Yamada S. Endoscopic tissue shielding with polyglycolic acid sheets, fibrin glue and clips to prevent delayed perforation after duodenal endoscopic resection. Dig Endosc. 2014;26(S2):41–5.
5. An T, Zhang S, Xu M, Zhou S, Wang W. Transcatheter embolization of peripheral renal artery for hemorrhagic urological emergencies using FuAiLe medical glue. Sci Rep. 2015;5:9106.
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献