Abstract
AbstractBackgroundTotal hip arthroplasty(THA)is widely used to treat end-stage hip disorders. Ceramic-on-ceramic total hip prostheses are widely used because of their durability. Alumina matrix composite (AMC), known as the fourth-generation ceramics, reduces implant fracture and wear rate compared to their predecessors. However, ceramic acetabular liner dissociation is a complication that necessitates revision of the AMC prostheses. To date, only few cases of AMC liner dissociation have been reported and all of which have been treated with revision surgery. Therefore, the prognosis of non-operated AMC liner dissociation remains unknown so far.Case presentationA 57-year-old man with avascular necrosis of the femoral head was treated with THA, wherein a Pinnacle® (DePuy, J&J, Warsaw, IN) acetabular cup and AMC liner were implanted. Intraoperative examination confirmed proper seating of the liner, whereas the initial postoperative radiograph revealed liner dissociation. The patient refused surgical revision due to the absence of symptoms and was discharged and followed-up. The patient made an uneventful recovery, and radiographic follow-up at 6-month post-operation showed that the liner was re-seated to its right position. No clinical or radiographic anomaly was found at the 15-month of postoperative follow-up.ConclusionsHere, we report an unprecedented case of AMC ceramic liner dissociation with spontaneous resolution. This case shows that ceramic liner dissociation could be asymptomatic, and careful postoperative examination of the patient is important. Spontaneous resolution is possible, but the underlying mechanism and the eligible patient to benefit from it must be investigated. Before clarifying these questions, revision surgery should be the first-line treatment.
Funder
President Foundation of Nanfang Hospital
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Rheumatology
Reference21 articles.
1. Jeffers JRT, Walter WL. Ceramic-on-ceramic bearings in hip arthroplasty: state of the art and the future. J Bone Joint Surg Br. 2012;94(6):735–45.
2. Massin P, Lopes R, Masson B, Mainard D, French H, Knee S. Does Biolox Delta ceramic reduce the rate of component fractures in total hip replacement? Orthop Traumatol Surg Res. 2014;100(6 Suppl):317-21.
3. Baek S-H, Kim JY, Han JW, Kim S-Y. Potential risk of AMC ceramic liner for dissociation after square seating. J Orthop Sci. 2018;23(3):600–3.
4. Lee YK, Ha YC, Yoo J-I, Jo WL, Kim K-C, Koo KH. Mid-term results of the BIOLOX delta ceramic-on-ceramic total hip arthroplasty. Bone Joint J. 2017;99-B(6):741–8.
5. Hamilton WG, McAuley JP, Dennis DA, Murphy JA, Blumenfeld TJ, Politi J. THA with Delta ceramic on ceramic: results of a multicenter investigational device exemption trial. Clin Orthop Relat Res. 2010;468(2):358–66.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献