Author:
Zhu Wenbin,Zhou Huan,Hu Zhe,Chen Hongyan,Liu Juan,Li Jin,Feng Xiaoyuan,Li Xueqin
Abstract
Abstract
Background
Trigger thumb is a pathologic condition of the digital pulleys and flexor tendons. To find a cutoff value of the cross-sectional area ratio of specific parts of the flexor pollicis longus tendon to diagnosis trigger thumb in the high-frequency ultrasound examination.
Methods
We evaluated 271 healthy volunteers and 57 patients with clinical diagnosis of trigger thumb. The cross-sectional area of the metacarpophalangeal joint of flexor pollicis longus tendon (C1) and the cross-sectional area of the midpoint of the first metacarpal of flexor pollicis longus tendon (C2) were analyzed.
Results
There is no difference between gender, age and left and right hands in the ratio of C1 to C2 (C1/ C2). The mean of C1/ C2 in the healthy thumb was 0.983 ± 0.103, which was significantly smaller in comparison to the diseased thumb (P < 0.05). Based on the receiver operating characteristic curve, we chose the diagnostic cut-off value for the C1/ C2 to be 1.362 and 1.153 in order to differ a trigger thumb from children and adults.
Conclusions
The C1/ C2 of the healthy thumb was relatively stable, with a mean value of 0.983 ± 0.103. The cutoff value of C1/C2 to distinguish healthy thumb from diseased thumb in children and adults were 1.362 and 1.153, respectively.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Rheumatology
Reference16 articles.
1. Akhtar S, Bradley MJ, Quinton DN, Burke FD. Management and referral for trigger finger/thumb. BMJ. 2005;331(7507):30–3.
2. Jeanmonod R, Harberger S, Waseem M. Trigger Finger. [Updated 2022 Aug 7]. In: StatPearls. Treasure Island: StatPearls Publishing; 2023. Available from: https://www.ncbi.nlm.nih.gov/books/NBK459310/.
3. Nimigan AS, Ross DC, Gan BS. Steroid injections in the management of trigger fingers. Am J Phys Med Rehabil. 2006;85(1):36–43.
4. Draghi F, Gitto S, Bianchi S. Injuries to the Collateral Ligaments of the Metacarpophalangeal and Interphalangeal Joints: Sonographic Appearance. J Ultrasound Med. 2018;37(9):2117–33.
5. Guerini H, Pessis E, Theumann N, et al. Sonographic appearance of trigger fingers. J Ultrasound Med. 2008;27(10):1407–13.