Improvement of absorbability, osteoconductivity, and strength of a β-tricalcium phosphate spacer for opening wedge high tibial osteotomy: clinical evaluations with 106 patients

Author:

Yamaguchi Jun,Kondo Eiji,Yasuda Kazunori,Onodera Jun,Yabuuchi Koji,Kaibara Takuma,Takami Kimiaki,Iwasaki Norimasa,Yagi Tomonori

Abstract

Abstract Background An ideal synthetic spacer for medial opening wedge high tibial osteotomy (MOWHTO) has not yet been developed. The authors have developed a new β-tricalcium phosphate (β-TCP) spacer with 60% porosity (N-CP60) by modifying the micro- and macro-pore structures of a conventional β-TCP spacer (CP60) that is widely used in clinical practice. The purpose of this study was to compare the absorbability, osteoconductivity, and in vivo strength of the N-CP60 spacer with those of the CP60 spacer, when used in MOWHTO. Methods First, the porosity, diameter distribution of macro- and micropores, and compressive strength of each β-TCP block were examined using methodology of biomaterial science. Secondly, a clinical study was performed using a total of 106 patients (106 knees) with MOWHTO, who were followed up for 18 months after surgery. In these knees, the N-CP60 and CP-60 spacers were implanted into 49 tibias and 57 tibias, respectively. The absorbability and osteoconductivity were radiologically evaluated by measuring the area of the implanted spacer remaining unabsorbed and assessing with the Hemert’s score, respectively. The incidence of cracking in the implanted spacers was determined using computed radiography. Statistical comparisons were made with non-parametric tests. The significance level was set at p = 0.05. Results The N-CP60 and CP60 blocks had almost the same porosity (mean, 61.0% and 58.7%, respectively). The diameter of macropores was significantly larger (p < 0.0001) in the N-CP60 block than in the CP60 block, while the diameter of micropores was significantly smaller (p = 0.019) in the N-CP60 block. The ultimate strength of the N-CP60 block (median, 36.8 MPa) was significantly greater (p < 0.01) than that of the CP60 block (31.6 MPa). As for the clinical evaluations, the absorption rate of the N-CP60 spacer at 18 months after implantation (mean, 48.0%) was significantly greater (p < 0.001) than that of the CP60 spacer (29.0%). The osteoconductivity of the N-CP60 spacer was slightly but significantly higher (p = 0.0408) than that of the CP60 spacer only in zone 1. The incidence of in vivo cracking of the posteriorly located N-CP60 spacer at one month (mean, 75.5%) was significantly lower (p = 0.0035) than that of the CP60 spacer (91.2%). Conclusions The absorbability, osteoconductivity, and compressive strength of the new N-CP60 spacer were significantly improved by modifying the macro- and micro-pore structures, compared with the conventional CP60 spacer. The N-CP60 spacer is more clinically useful than the CP60 spacer. Trial registration number H29-0002.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3