Application of piecewise VMAT technique to whole-brain radiotherapy with simultaneous integrated boost for multiple metastases

Author:

Xu Yuan,Xu Yingjie,Men Kuo,Xiao Jianping,Dai Jianrong

Abstract

Abstract Purpose This study implemented a piecewise volumetric modulated arc therapy (P-VMAT) for realizing whole-brain radiation therapy (WBRT) with simultaneous integrated boost (SIB) for multiple brain metastases (> 40 metastases) with a conventional C-arm linear accelerator. Materials and methods This study retrospectively analyzed 10 patients with multiple brain metastases (40–120 metastases, median 76), who underwent WBRT and SIB using helical tomotherapy (HT). The prescribed doses were 40 Gy/20 f and 60 Gy/20 f for WBRT and SIB, respectively. Corresponding new HT plans were designed with P-VMAT using 7 arcs. For each arc, the collimator was rotated to 45°, and the field width was limited to 2.5 cm with 0.5 cm overlap with adjacent arcs. Thus, each arc covered only one section of the brain target volume. A conventional dual arc VMAT (DA-VMAT) plan was also designed. HT, P-VMAT, and DA-VMAT plans were compared using dose distribution reviews and dosimetric parameters. ArcCHECK phantom measurements were performed for verification of P-VMAT plans. Results No significant differences in the mean coverage of the whole-brain target and metastases were observed between HT and P-VMAT (p > 0.05). The conformity index for the whole-brain target improved with P-VMAT compared with HT (p < 0.05). Furthermore, the volume of 44 Gy V44 (110% of prescribed dose for WBRT) received for whole-brain significantly reduced with P-VMAT from 38.2 ± 12.9% to 23.3 ± 9.4% (p < 0.05), and the maximum dose for organs at risks such as the hippocampus, optical nerve, optical chiasm, and spinal cord declined with P-VMAT (p < 0.05). Unlike HT and P-VMAT, DA-VMAT was clinically unacceptable because V44 in the whole-brain was too high (54.7 ± 8.2%). The mean absolute dose gamma passing rate for P-VMAT plans was 97.6 ± 1.1% (3%/3 mm criterion, 10%). Conclusions P-VMAT is favorable for WBRT and SIB for multiple brain metastases. It provides comparable coverage of whole-brain target and SIB, with better conformity, lower V44, and better dose sparing of organs at risk compared with HT. Furthermore, results show that DA-VMAT fails clinical practice even for a relatively large number of brain metastases with a high degree of plan complexity. The patient specific verification demonstrates the feasibility of P-VMAT for clinical application.

Funder

National Natural Science Foundation of China

National Key Projects of Research and Development of China

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Oncology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3