Impact of four-dimensional cone-beam computed tomography on target localization for gastric mucosa-associated lymphoid tissue lymphoma radiotherapy: reducing planning target volume

Author:

Shimohigashi YoshinobuORCID,Toya Ryo,Saito Tetsuo,Kono Yumiko,Doi Yasuhiro,Fukugawa Yoshiyuki,Watakabe Takahiro,Matsumoto Tadashi,Kai Yudai,Maruyama Masato,Oya Natsuo

Abstract

Abstract Background Radiotherapy of gastric mucosa-associated lymphoid tissue (MALT) lymphoma should be delivered to the entire stomach with planning target volume (PTV) that accounts for variations in stomach volume, respiratory movement, and patient set-up error. In this study, we evaluated whether the use of four-dimensional cone-beam computed tomography (4D-CBCT) reduces the PTV. Methods Eight patients underwent radiotherapy with 15 fractions of gastric MALT lymphoma using 4D-CBCT. PTV structures of 5–30 mm margins (5 mm intervals) from the clinical target volume (CTV) delineated based on the 4D-CT images (CTV-4D) were generated. For the target localization, we performed matching based on skin marking (skin matching), bone anatomy (bone matching), and stomach anatomy (4D soft-tissue matching) based on registration between planning CT and 4D-CBCT images from 10 phases. For each patient, we calculated the covering ratio (CR) of the stomach with variable PTV structures, based on the 4D-CBCT images, with a total of 150 phases [CR (%) = (number of covering phases/150 phases) × 100], for three target localization methods. We compared the CR values of the different target localization methods and defined the PTV with an average CR of ≥ 95% for all patients. Results The average CR for all patients increased from 17.9 to 100%, 19.6 to 99.8%, and 33.8 to 100%, in the skin, bone, and 4D soft-tissue matchings, respectively, as the PTV structures increased from 5 to 30 mm. The CR obtained by 4D soft-tissue matching was superior to that obtained by skin (P = 0.013) and bone matching (P = 0.008) for a PTV structure of 15 mm margin. The PTV required an additional margin of 20 mm (average CR: 95.2%), 25 mm (average CR: 99.1%), and 15 mm (average CR: 98.0%) to CTV-4D for the skin, bone, and 4D soft-tissue matchings, respectively. Conclusions This study demonstrates that the use of 4D-CBCT reduces the PTV when applying 4D soft-tissue matching, compared to skin and bone matchings. Additionally, bone matching does not reduce the PTV as compared with traditional skin matching.

Funder

Japan Society for the Promotion of Science (JSPS), KAKENHI

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3