Using the intraoperative hand held probe without lymphoscintigraphy or using only dye correlates with higher sensory morbidity following sentinel lymph node biopsy in breast cancer: A review of the literature

Author:

Kim Suk Chul,Kim Dong Wook,Moadel Renee M,Kim Chun K,Chatterjee Samprit,Shafir Michail K,Travis Arlene,Machac Josef,Krynyckyi Borys R

Abstract

Abstract Background There are no studies that have directly investigated the incremental reduction in sensory morbidity that lymphoscintigraphy images (LS) and triangulated body marking or other skin marking techniques provide during sentinel lymph node biopsy (SLNB) compared to using only the probe without LS and skin marking or using only dye. However, an indirect assessment of this potential for additional sensory morbidity reduction is possible by extracting morbidity data from studies comparing the morbidity of SLNB to that of axillary lymph node dissection. Methods A literature search yielded 13 articles that had data on sensory morbidity at specific time points on pain, numbness or paresthesia from SLNB that used radiotracer and probe or used only dye as a primary method of finding the sentinel node (SN). Of these, 10 utilized LS, while 3 did not utilize LS. By matching the data in studies not employing LS to the studies that did, comparisons regarding the percentage of patients experiencing pain, numbness/paresthesia after SLNB could be reasonably attempted at a cutoff of 9 months. Results In the 7 studies reporting on pain after 9 months (> 9 months) that used LS (1347 patients), 13.8% of patients reported these symptoms, while in the one study that did not use LS (143 patients), 28.7% of patients reported these symptoms at > 9 months (P < 0.0001). In the 6 studies reporting on numbness and/or paresthesia at > 9 months that used LS (601 patients), 12.5% of patients reported these symptoms, while in the 3 studies that did not use LS (229 patients), 23.1% of patients reported these symptoms at > 9 months (P = 0.0002). Similar trends were also noted for all these symptoms at ≤ 9 months. Conclusion Because of variations in techniques and time of assessing morbidity, direct comparisons between studies are difficult. Nevertheless at a minimum, a clear trend is present: having the LS images and skin markings to assist during SLNB appears to yield more favorable morbidity outcomes for the patients compared to performing SLNB with only the probe or performing SLNB with dye alone. These results are extremely pertinent, as the main reason for performing SLNB itself in the first place is to achieve reduced morbidity.

Publisher

Springer Science and Business Media LLC

Subject

Oncology,Surgery

Cited by 24 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3