Treatment of odontoid fractures with odontoid screws is an established method for fusion. However, it is facilitated by using advanced equipment in the operating theatre not always available as in developing countries.
Objectives
In this study we aim to outline the important key points for successful placement of odontoid screw in the absence of advanced tools, e.g. navigation or O-arm.
Materials and methods
Fifteen patients suffering from type II odontoid fractures were managed with single odontoid screw. Reduction of the fractures was achieved. A simple instrument set was used with the help of a single plane image intensifier. Longitudinal incision was used in 4 cases, and transverse incision was used in the remaining eleven cases. Anatomical identification of the midline helped to mark the entry point. The entry point used was millimetres below the anteroinferior edge of the axis vertebra. A short-headed screw was used.
Results
Road traffic accident was the only mechanism of trauma reported in our study. All of the patients were neurologically intact. All of the patients remained neurologically intact after the procedure. There were no instances of wrong trajectory of the screw in our study. During follow-up, we found good union of all the fractures. Only 2 cases suffered from mild dysphagia.
Conclusion
Fixation of odontoid fractures by anterior odontoid screws appears to be a safe and feasible procedure even in underequipped theatres. Anatomical knowledge helps in determining midline. Various modifications can help in overcoming shortcomings.
Publisher
Springer Science and Business Media LLC
Subject
Psychiatry and Mental health,Neurology (clinical),General Neuroscience,Pshychiatric Mental Health,Surgery
Reference14 articles.
1. Mazur MD, Mumert ML, Bisson EF, Schmidt MH. Avoiding pitfalls in anterior screw fixation for type II odontoid fractures. Neurosurg Focus. 2011;31(4):E7.
2. Smith HE, Vaccaro AR, Maltenfort M, Albert TJ, Hilibrand AS, Anderson DG, et al. Trends in surgical management for type II odontoid fracture: 20 years of experience at a regional spinal cord injury center. Orthopedics. 2008;31(7):650.
3. Rajasekaran S, Jaiswal A, Shetty A. Role of intraoperative Iso-C based navigation in challenging spine trauma. Indian J Orthop. 2007;41(4):312.
4. Wu J-C, Wadhwa R, Than K, Mummaneni P. Complication avoidance and management using the O-arm for odontoid screw fixation: technical note. Cureus. 2014;6(11):e225. https://doi.org/10.7759/cureus.225.
5. Grauer JN, Shafi B, Hilibrand AS, Harrop JS, Kwon BK, Beiner JM, et al. Proposal of a modified, treatment-oriented classification of odontoid fractures. Spine J. 2005;5(2):123–9.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献