Transurethral plasmakinetic resection versus enucleation for benign prostatic hyperplasia: comparison of intraoperative safety profiles based on endoscopic surgical monitoring system

Author:

Jin Qi,Yang En-Guang,Zhang Yun-Xin,Mi Jun,Dong Zhi-Long,Yang Li,Tian Jun-Qiang,Wang Juan,Wang Zhi-Ping

Abstract

Abstract Objective To compare the intraoperative safety profiles of transurethral plasmakinetic resection of the prostate (PK-TURP) with transurethral plasmakinetic endoscopic enucleation of the prostate (PK-EEP) in the treatment of benign prostatic hyperplasia (BPH) based on endoscopic surgical monitoring system (ESMS). Methods A total of 128 patients who were diagnosed with BPH were stratified based on prostate volume (PV) and accepted PK-EEP or PK-TURP treatment at 1:1 ratio. The ESMS as a novel method was used to monitor blood loss and fluid absorption during the operation. Clinical parameters such as intraoperative blood loss volume, fluid absorption volume, operation time, tissue weight of resection, preoperative and postoperative red blood cell count (RBC), hemoglobin concentration (HB), hematocrit (HCT), electrolyte, postoperative bladder irrigation time, indwelling catheter time, hospital stay time and other associated complications were documented and compared between two groups. Results No significant differences in majority of baseline characteristics were observed among patients with different prostate volumes between two surgical methods. For patients with prostate volume < 40 ml, the average operation time of patients who received PK-EEP treatment was much more than those who received PK-TURP (P = 0.003). On the other hand, for patients with prostate volume > 40 ml, the PK-TURP surgery was associated with a significant increase in intraoperative blood loss (P = 0.021, in PV 40–80 ml group; P = 0.014, in PV > 80 ml group), fluid absorption (P = 0.011, in PV 40–80 ml group; P = 0.006, in PV > 80 ml group) and postoperative bladder irrigation time as well as indwelling catheter time but decrease in resected tissue weight compared to the PK-EEP treatment. Conclusion The ESMS plays an important role in comparison of intraoperative safety profiles between PK-TURP and PK-EEP. Our data suggest that PK-TURP treatment is associated with a decreased operation time in patients with prostate volume < 40 ml and the PK-EEP treatment is associated with decreased intraoperative blood loss, fluid absorption and increased tissue resection for patients with prostate volume > 40 ml. Our results indicate that the size of prostate should be considered when choosing the right operation method.

Publisher

Springer Science and Business Media LLC

Subject

Urology,Reproductive Medicine,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3