A comparison of pin site complications between large and small pin diameters in robotic-assisted total knee arthroplasty

Author:

Desai Sohil S.,Kunes Jennifer A.ORCID,Held Michael B.,Ren Mark,deMeireles Alirio J.,Geller Jeffrey A.,Shah Roshan P.,Cooper H. John

Abstract

Abstract Purpose Robotic-assisted total knee arthroplasty typically necessitates use of tracking pins, which can vary in diameter. Complications such as infections and fractures at the pin-site have been observed, but clarification of the effect of pin diameter on complication is needed. The aim of this study is to compare the pin-related complication rates following robotic-assisted total knee arthroplasty between 4.5 mm and 3.2 mm diameter pins. Methods In this retrospective cohort study, 90-day pin-site complication rates after robotic-assisted total knee arthroplasty were compared between 4.5 mm diameter and 3.2 mm diameter groups. In total, 367 patients were included: 177 with large pin diameter and 190 with small pin diameter. All four pin sites were evaluated using postoperative radiographs. Cases without orthogonal views or visualization of all four pin tracts were noted. Multivariate logistic regression was used to control for age, which differed between the two cohorts. Results The rate of pin-site complications was 5.6% in the large pin diameter cohort and 2.6% in the small pin diameter cohort, with no statistically significant difference between the groups. The adjusted odds ratio for complications in small compared to large diameter group was 0.48, with a p-value of 0.18. The most common pin-site complication was infection/persistent drainage, found in 1.9% of patients, followed by intraoperative fracture of the second cortex in 1.4%. Intraoperative fracture could not be ruled out in 96 cases due to inadequate radiographic visualization of all pin sites. There was one postoperative pin-site fracture in the large diameter cohort, which required operative fixation. Conclusion This study demonstrates no statistically significant difference in pin-site complication rates after robotic-assisted total knee arthroplasty between 4.5 mm and 3.2 mm pin diameter cohorts, although there was a trend towards increased intraoperative and postoperative pin-site fractures in the 4.5 mm group.

Publisher

Wiley

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3