Author:
Sun Xiaoning,Lu Shuyang,Yang Shouguo,Lai Hao,Chen Hao,Hong Tao,Wang Chunsheng
Abstract
Abstract
Background
The primary experience of open triple-branched stent graft placement for acute aortic arch dissection was reported.
Methods
Between January 2011 and October 2011, 13 well-selected patients (mea age, 46±8.2 years; approximate range, 30~58 years) with acute aortic arch dissection underwent open triple-branched stent graft placement for total arch reconstruction. The triple-branched stent graft was a branched 1-piece graft consisting of a self-expandable nitinol stent and polyester vascular graft fabric (Yuhengjia Sci Tech Corp Ltd, Beijing, China).During hypothermic circulatory arrest, through the transverse incision of the ascending aorta, the main graft of the triple-branched stent graft was inserted into the true lumen of the arch and proximal descending aorta, and then each sidearm graft was positioned one by one into the aortic branch. Once the main graft and sidearm grafts were properly positioned, the restraining strings were withdrawn and then the main graft and sidearm grafts were deployed. Enhanced electric beam computed tomography was performed in each patient before discharge to evaluate the postoperative time course of the residual false lumen.
Results
Open triple-branched stent graft placement was technically successful in all patients. The mean cardiopulmonary bypass time, aortic cross-clamp time and arrest time were 138.40±47.75 min, 70.60±28.94 min and 28.60±12.48 min, respectively. All patients were discharged from hospital. Their computed tomographic scans postoperatively showed that all stent grafts were fully opened and not kinked, there was no blood flow surrounding the triple-branched stent graft.
Conclusion
Open triple-branched stent graft placement is a new effective technique for total arch reconstruction in acute arch dissection.
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine
Reference14 articles.
1. Borst HG, Walterbusch G, Schaps D: Extensive aortic replacement using the “elephant trunk” prosthesis. Thorac Cardiovasc Surg. 1983, 31: 37-40. 10.1055/s-2007-1020290.
2. Heinemann MK, Buehner B, Jurmann MJ, Borst HG: Use of the “elephant trunk technique” in aortic surgery. Ann Thorac Surg. 1995, 60: 2-7.
3. Svensson LG: Rationale and technique for replacement of the ascending aorta, arch, and distal aorta using a modified elephant trunk procedure. J Card Surg. 1992, 7: 301-321. 10.1111/j.1540-8191.1992.tb01020.x.
4. Crawford ES, Coselli JS, Svensson LG, Safi HJ, Hess KR: Diffuse aneurysmal disease (chronic aortic dissection, Marfan, and mega aorta syndromes) and multiple aneurysm: treatment by subtotal and total aortic replacement emphasizing the elephant trunk operation. Ann Surg. 1990, 211: 521-537. 10.1097/00000658-199005000-00002.
5. Kato M, Ohnishi K, Kaneko M, Ueda T, Kishi D, Mizushima T, Matsuda H: New graft-implanting method for thoracic aortic aneurysm or dissectionwith a stented graft. Circulation. 1996, 94 (suppl II): II188-II193.
Cited by
6 articles.
订阅此论文施引文献