Application of Regent mechanical valve in patients with small aortic annulus: 3-year follow-up

Author:

Zhao Dong,Wang Chunsheng,Hong Tao,Pan Cuizhen,Guo Changfa

Abstract

Abstract Background Aortic valve replacement (AVR) with a small aortic annulus is always challenging for the cardiac surgeon. In this study, we sought to evaluate the midterm performance of implantation with a 17-mm or 19-mm St. Jude Medical Regent (SJM Regent) mechanical valve in retrospective consecutive cohort of patients with small aortic annulus (diameter ≤ 19 mm). Methods From January 2008 to April 2011, 40 patients (31 female, mean age = 47.2 ± 5.8 years) with small aortic annulus (≤19 mm in diameter) underwent aortic valve replacement with a 17-mm or 19-mm St. Jude Medical Regent (SJM Regent) mechanical valve. Preoperative mean body surface area, New York Heart Association class, and mean aortic annulus were 1.61 ± 0.26 m2, 3.2 ± 0.4, and 18 ± 1.4 mm respectively. Patients were divided into two groups, according to the implantation of 17 mm SJM Regent mechanical valve (group 1, n = 18) or 19 mm SJM Regent valve (group 2, n = 22). All patients underwent echocardiography examination preoperatively and at one year post-operation. Results There were no early deaths in either group. Follow-up time averaged 36 ± 17.6 months. The mean postoperative New York Heart Association class was 1.3 ± 0.6 (p < 0.001). By echocardiography, in group 1, the left ventricular ejection fraction (LVEF), left ventricular fraction shortening (LVFS), and the indexed effective orifice area (EOAI) increased from 43.7% ± 11.6%, 27.3% ± 7.6%, and 0.70 ± 0.06 cm2/m2 to 69.8 ± 9.3%, 41.4 ± 8.3%, and 0.92 ± 0.10 cm2/m2 respectively (P < 0.05), while the left ventricular mass index (LVMI), and the aortic transvalvular pressure gradient decreased from 116.4 ± 25.4 g/m2, 46.1 ± 8.5 mmHg to 86.7 ± 18.2 g/m2 , 13.7 ± 5.2 mmHg respectively. In group 2, the LVEF, LVFS and EOAI increased from 45.9% ± 9.7%, 30.7% ± 8.0%, and 0.81 ± 0.09 cm2/m2 to 77.4% ± 9.7%, 44.5% ± 9.6%, and 1.27 ± 0.11 cm2/m2 respectively, while the LVMI, and the aortic transvalvular pressure gradient decreased from 118.3 ± 27.6 g/m2, 44.0 ± 6.7 mmHg to 80.1 ± 19.7 g/m2, 10.8 ± 4.1 mmHg as well. The prevalence of PPM was documented in 2 patients in Group 1. Conclusions Patients with small aortic annulus and body surface area, experienced satisfactory clinical improvement after aortic valve replacement with modern SJM Regent bileaflet prostheses.

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3