New biomarkers for the diagnosis of pleural effusion

Author:

El-Sokkary Raafat T.,Abuelkassem Nermen M.ORCID,Seddik Mohamed Ismail,Metwally Ahmed

Abstract

Abstract Background Persistent undiagnosed effusion is present in approximately 15% of all causes of exudative effusion. Pleural effusion caused by immunoglobulin G4 (IgG4) is a new type of pleural effusion. Tumor markers such as Carcinoembryonic antigen (CEA) may play a role in the diagnosis of malignant pleural effusion. This study aimed to evaluate the use of serum Immunoglobulin G4 and carcinoembryonic antigen in diagnosing pleural effusion. Methods This observational descriptive cross-sectional study comprised 89 individuals with exudative pleural effusion who visited the Assiut university hospital's chest department. All patients were examined and asked about their medical history. Also, chest X-ray, MSCT chest, transthoracic ultrasonography, pleural fluid analysis and cytology, serum level of carcinoembryonic antigen, and immunoglobulin G4 were performed. In addition, pleural biopsy, bronchoscopy, and thoracoscopy were performed when required. Results In comparison to another diagnosis, the level of serum IgG 4 was observed to be substantially greater in individuals with IgG4-associated effusion (725± 225.45). Patients with malignant mesothelioma (70± 16.24) and metastatic adenocarcinoma (93.52± 19.34) had lower levels of IgG4. In contrast, the serum level of CEA was significantly higher in individuals with malignant mesothelioma (79.50± 29.47) and metastatic adenocarcinoma (68.71± 28.98). Patients with para-pneumonic effusion had a minor serum level of CEA (0.36 ± 0.26). At cutoff point > 152 mg/dl serum IgG-4 had 100% sensitivity and 94% specificity in the diagnosis of IgG4 related pleural effusion with an overall accuracy of 95.3% and area under the curve of 0.97. At the cutoff point > 5 ng/ml serum CEA had 77% sensitivity and 100% specificity in diagnosing malignant pleural effusion with an overall accuracy of 91.1% and area under the curve of 0.88. Conclusion Serum IgG4 higher than 152 mg/dl has good diagnostic accuracy in cases of undiagnosed pleural effusion. Carcinoembryonic antigen aids in diagnosing malignant pleural effusion with a cutoff point higher than 5 ng/ml in serum. Trial registration ClinicalTrials.gov registration ID NCT03260088

Publisher

Springer Science and Business Media LLC

Subject

General Earth and Planetary Sciences,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3