An analysis of the correlation between diabetic retinopathy and preretinal oxygen tension using three-dimensional spoiled gradient-recalled echo sequence imaging

Author:

Zhou Min-Jie,Shao Ju-Wei,Pu Jian,Xiang Shu-Tian,Liang Yi,He Qian,Su Wei,Liu Cheng

Abstract

Abstract Background The aims of this study were to evaluate the levels of preretinal oxygen tension in patients with diabetes who did not have hypertension by using three-dimensional spoiled gradient-recalled (3D-SPGR) echo sequence imaging and to explore the correlation between diabetic retinopathy (DR) and changes in preretinal oxygen tension. Method This study involved 15 patients with type 2 diabetes without hypertension, who were divided into a diabetic retinopathy (DR) group (n = 10 eyes) and a diabetic non-retinopathy (NDR) group (n = 20 eyes), according to the results of a fundus photography test. Another healthy control group (n = 14 eyes) also participated in the study. The preretinal vitreous optic disc area, nasal side, and temporal side signal intensity of the eyes was assessed before and after oxygen inhalation with the use of 3D-SPGR echo magnetic resonance imaging (MRI). The signal acquisition time was 10, 20, 30, 40, and 50 min after oxygen inhalation. Results The results showed that, in the DR and NDR groups, the preretinal vitreous oxygen tension increased rapidly at 10 min after oxygen inhalation and peaked at 30–40 min, and the increased slope of the DR group was higher than that of the NDR group. The oxygen tension of the preretinal vitreous gradually increased after oxygen inhalation, and the difference between the DR and NDR groups and the control group was statistically significant (P < 0.05). The preretinal vitreous oxygen tension was higher in the optic disc, temporal side, and nasal side in the NDR group than in the control group, and the difference was statistically significant (P < 0.05). The maximum slope ratios of the optic disc and the temporal side of the DR group were greater than those of the control group, and the difference was statistically significant (P < 0.05). Conclusion Three-dimensional-SPGR echo MRI sequencing technology is useful for detecting preretinal oxygen tension levels in patients with diabetes. It can be used as one of the functional and imaging observation indicators for the early diagnosis of DR.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3