Patient-adapted organ absorbed dose and effective dose estimates in pediatric 18F-FDG positron emission tomography/computed tomography studies

Author:

Quinn Brian M.ORCID,Gao Yiming,Mahmood Usman,Pandit-Taskar Neeta,Behr Gerald,Zanzonico Pat,Dauer Lawrence T.

Abstract

Abstract Background Organ absorbed doses and effective doses can be used to compare radiation exposure among medical imaging procedures, compare alternative imaging options, and guide dose optimization efforts. Individual dose estimates are important for relatively radiosensitive patient populations such as children and for radiosensitive organs such as the eye lens. Software-based dose calculation methods conveniently calculate organ dose using patient-adjusted and examination-specific inputs. Methods Organ absorbed doses and effective doses were calculated for 429 pediatric 18F-FDG PET-CT patients. Patient-adjusted and scan-specific information was extracted from the electronic medical record and scanner dose-monitoring software. The VirtualDose and OLINDA/EXM (version 2.0) programs, respectively, were used to calculate the CT and the radiopharmaceutical organ absorbed doses and effective doses. Patients were grouped according to age at the time of the scan as follows: less than 1 year old, 1 to 5 years old, 6 to 10 years old, 11 to 15 years old, and 16 to 17 years old. Results The mean (+/− standard deviation, range) total PET plus CT effective dose was 14.5 (1.9, 11.2–22.3) mSv. The mean (+/− standard deviation, range) PET effective dose was 8.1 (1.2, 5.7–16.5) mSv. The mean (+/− standard deviation, range) CT effective dose was 6.4 (1.8, 2.9–14.7) mSv. The five organs with highest PET dose were: Urinary bladder, heart, liver, lungs, and brain. The five organs with highest CT dose were: Thymus, thyroid, kidneys, eye lens, and gonads. Conclusions Organ and effective dose for both the CT and PET components can be estimated with actual patient and scan data using commercial software. Doses calculated using software generally agree with those calculated using dose conversion factors, although some organ doses were found to be appreciably different. Software-based dose calculation methods allow patient-adjusted dose factors. The effort to gather the needed patient data is justified by the resulting value of the characterization of patient-adjusted dosimetry.

Funder

NIH/NCI

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3