Prehospital monitoring of cerebral circulation during out of hospital cardiac arrest ? A feasibility study

Author:

Henningsson Anna,Lannemyr Lukas,Angerås Oskar,Björås Joakim,Bergh Niklas,Herlitz Johan,Redfors Bengt,Lundgren Peter

Abstract

Abstract Background About two-thirds of the in-hospital deaths after out-of-hospital cardiac arrests (OHCA) are a consequence of anoxic brain injuries, which are due to hypoperfusion of the brain during the cardiac arrests. Being able to monitor cerebral perfusion during cardiopulmonary resuscitation (CPR) is desirable to evaluate the effectiveness of the CPR and to guide further decision making and prognostication. Methods Two different devices were used to measure regional cerebral oxygen saturation (rSO2): INVOS™ 5100 (Medtronic, Minneapolis, MN, USA) and Root® O3 (Masimo Corporation, Irvine, CA, USA). At the scene of the OHCA, advanced life support (ALS) was immediately initiated by the Emergency Medical Services (EMS) personnel. Sensors for measuring rSO2 were applied at the scene or during transportation to the hospital. rSO2 values were documented manually together with ETCO2 (end tidal carbon dioxide) on a worksheet specially designed for this study. The study worksheet also included a questionnaire for the EMS personnel with one statement on usability regarding potential interference with ALS. Results Twenty-seven patients were included in the statistical analyses. In the INVOS™5100 group (n = 13), the mean rSO2 was 54% (95% CI 40.3–67.7) for patients achieving a return of spontaneous circulation (ROSC) and 28% (95% CI 12.3–43.7) for patients not achieving ROSC (p = 0.04). In the Root® O3 group (n = 14), the mean rSO2 was 50% (95% CI 46.5–53.5) and 41% (95% CI 36.3–45.7) (p = 0.02) for ROSC and no ROSC, respectively. ETCO2 values were not statistically different between the groups. The EMS personnel graded the statement of interference with ALS to a median of 2 (IQR 1–6) on a 10-point Numerical Rating Scale. Conclusion Our results suggest that both INVOS™5100 and ROOT® O3 can distinguish between ROSC and no ROSC in OHCA, and both could be used in the pre-hospital setting and during transport with minimal interference with ALS.

Funder

Västra Götalandsregionen

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine,Emergency Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3