Chronology of cardiac dysfunction after permanent pacemaker implantation: an observational 2 year prospective study in North India

Author:

Gupta Harshit,Showkat Hakim IrfanORCID,Aslam Naved,Tandon Rohit,Wander G. S.,Gupta Shweta,Anwar Sadaf,Sohil Mohd Maqbool

Abstract

Abstract Background The purpose of this study is to evaluate cardiac functions using transthoracic echocardiography, change in lead parameters and electrocardiogram (ECG) morphology in patients undergoing permanent pacemaker implantation over a follow-up period of 6 months. Methods This is a prospective study in patients undergoing permanent pacemaker implantation in a tertiary care hospital. Patients undergoing permanent pacemaker implantation were enrolled for up to one year and Echocardiographic parameters (by 2 blind operators) and ECG parameters were recorded at admission (within 24 h), before discharge (within 7 days of pacemaker implantation), after 1 month (± 7 days) and after 6 months (± 7 days) of follow-up. Results A total of 96 patients (60.4% males and 39.6% female, mean age 66.65 years) were implanted with permanent pacemaker. The mean QRS duration was 133.18 ms and increased significantly to 146.03 ms by 6 months despite septal lead placement in majority (92%) of patients. The mean baseline ejection fraction of 51.47 decreased significantly to 47.83 by 6 months. Diastolic parameters like left atrial volume index, early to late diastolic transmitral flow velocity (E/A) and early diastolic mitral annular tissue velocity (E/e′) showed a significant increase (> 5%) from baseline by the end of first week. By the end of first month, systolic dysfunction of RV sets in with significant (> 5%) change from baseline in parameters like Right ventricle myocardial performance index, transannular plane systolic excursion and right ventricle systolic excursion velocity (RVS′). Conclusion We have observed that pacemaker recipients with baseline reduced left ventricle (LV) systolic functions perform significantly worse compared to those with baseline normal cardiac functions and had a higher rate of deterioration of LV function. RV dysfunction is the first abnormality that occurs, by 1 week followed by LV dysfunction which starts by 1 month and the diastolic dysfunctions precede the systolic dysfunction. QRS duration also showed a gradual increase despite septal lead placement in majority (92%) and lead parameters showed no significant change over 6 months.

Publisher

Springer Science and Business Media LLC

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3