Evaluation of diurnal and postural intracranial pressure employing telemetric monitoring in idiopathic intracranial hypertension

Author:

Mitchell James LORCID,Buckham RebeccaORCID,Lyons HannahORCID,Walker Jessica KORCID,Yiangou AndreasORCID,Sassani MatildeORCID,Thaller MarkORCID,Grech OliviaORCID,Alimajstorovic ZerinORCID,Julher Marianne,Tsermoulas Georgios,Brock KristianORCID,Mollan Susan PORCID,Sinclair Alexandra JORCID

Abstract

Abstract Objectives Intracranial pressure (ICP) has been thought to vary diurnally. This study evaluates diurnal ICP measurements and quantifies changes in ICP occurring with changes in body posture in active idiopathic intracranial hypertension (IIH). Methods This prospective observational study utilized telemetric ICP monitoring in people with active IIH. Participants had the Raumedic p-Tel ICP intraparenchymal device (Raumedic, Hembrechts, Germany) surgically inserted. Changes in ICP in the supine position were evaluated. Then, the ICP was measured in the standing, sitting, supine, left lateral decubitus positions and with coughing and bending. Ultimately, changes in ICP over the course of 24 h were recorded. ISRCTN registration number 12678718. Results 15 women were included, mean (standard deviation) age 29.5 (9.5) years, body mass index 38.1 (6.2) kg/m2, and baseline mean ICP of 21.2 (4.8) mmHg (equivalent to 28.8 (6.5) cmCSF). Mean ICP rose with the duration in the supine position 1.2 (3.3) mmHg over 5-minutes (p = 0.175), 3.5 (2.8) mmHg over 30-minutes (p = 0.0002) and by a further 2.1 (2.2) mmHg over 3 h (p = 0.042). Mean ICP decreased by 51% when moving from the supine position to standing (21.2 (4.8) mmHg to 10.3 (3.7) mmHg respectively, p = 0.0001). Mean ICP increased by 13% moving from supine to the left lateral decubitus position (21.2 (4.8) mmHg to 24.0 (3.8) mmHg, p = 0.028). There was no significant difference in ICP measurements at any point during the daytime, or between 5-minute standing or supine recordings and prolonged ambulatory daytime and end of night supine recordings respectively. ICP, following an initial drop, increased progressively in conjunction with lying supine position from 23:00 h to 07:00 h by 34% (5.2 (1.9) mmHg, p = 0.026). Conclusion This analysis demonstrated that ICP does not appear to have a diurnal variation in IIH, but varies by position and duration in the supine position. ICP rose at night whilst the patient was continuously supine. Furthermore, brief standing and supine ICP measures in the day predicted daytime prolonged ambulatory measures and end of night peak ICP respectively. This knowledge gives reassurance that ICP can be accurately measured and compared at any time of day in an ambulant IIH patient. These are useful findings to inform clinical measurements and in the interpretation of ICP analyses in IIH. Trial registration ISTCRN (12678718).

Funder

Ministry of Defence

Association of British Neurologists and Guarantors of the Brain fellowship

Brain Research UK

National Institute for Health Research (NIHR) clinician scientist fellowship

Medical Research Council

Sir Jules Thorn Award for Biomedical Science

Publisher

Springer Science and Business Media LLC

Subject

Cellular and Molecular Neuroscience,Developmental Neuroscience,Neurology,General Medicine

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3