Abstract
Abstract
Background
To evaluate the efficacy of micro-incision vitrectomy surgery (MIVS) using Lumera and Resight non-contact sutureless wide-angle viewing systems (WAVS) for primary rhegmatogenous retinal detachment (RRD), and to analyze the anatomical and visual outcomes.
Methods
The retrospective, non-comparative, interventional case series reported here was conducted from June 2014 through November 2016. Enrolled patients presented with primary RRD and received MIVS with/without cryopexy by one surgeon using the Lumera and Resight non-contact sutureless WAVS. All patients were followed-up for a minimum of 12 months. Variables collected included patient demographics, best-corrected visual acuity, and macular status. The number and position of retinal break(s), and the use of cryopexy, were also recorded. Outcome measures included operative time, single-operation anatomical success rate, final anatomical success rate, recurrent rate, postoperative best-corrected visual acuity, and surgical complications. The end points were operative time, anatomical outcome, and functional outcome.
Results
In total, 110 eyes from 110 patients (68 men and 42 women) were treated. Of these, 103 (93%) eyes were reattached after primary vitrectomy. One hundred ten eyes (100%) reached final anatomical success. The mean operative time was 50.55 min. Multivariate analyses were performed with best model selection principle based on general linear model by Akaike Information Criteria for detecting possible factors related to operation time, and with multivariate logistic regression analysis for revealing probable clinical parameters which might influence the anatomical outcome after first operation and final visual outcome. Intraoperative cryopexy and multiple breaks increased operative time significantly. More favorable BCVA was significantly correlated with shorter operation time and the preoperative macula-on status. Multivariate logistic regression on the group of patients who have received the cataract surgery revealed that the pre-operative BCVA is a significant factor which can predict the visual outcome after MIVS.
Conclusions
The outcome of primary RRD repaired by MIVS using the Lumera and Resight sutureless WAVS was not inferior to any other published method. This instrument combination resulted in a relatively rapid and comfortable procedure without serious postoperative complications. Cryopexy and multiple breaks affected operative time significantly. Shorter operative times and preoperative macula-on status are associated with better final visual outcomes.
Publisher
Springer Science and Business Media LLC
Subject
Ophthalmology,General Medicine
Cited by
18 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献