Abstract
AbstractInformation on the properties of nailed joints with decayed member is necessary to evaluate the remaining structural properties of timber constructions. In this study, loading tests were conducted on nailed joints parallel and perpendicular to the grain with decayed members, and the relationship between the decrease in shear properties and the loading direction to the grain was investigated. After the loading tests, the extent of decay of the specimens was evaluated by the penetration depth of Pilodyn and the decay depth, and these were compared with the shear properties of the nailed joints. The nailed joints with decay had a low load at the initial deformation, regardless of the loading direction to the grain. The initial stiffness, yield resistance, and maximum resistance of the nailed joints parallel to the grain were negatively correlated with the Pilodyn penetration depth, and those of the nailed joints perpendicular to the grain showed no significant correlation with the Pilodyn penetration depth at the 5% level. The initial stiffness, yield resistance, and maximum resistance of the nailed joints parallel to the grain tended to decrease with increasing decay depth, and those of the nailed joints perpendicular to the grain did not exhibit this tendency. The shear properties of the nailed joints significantly decreased at small decay depths.
Funder
japan society for the promotion of science
Publisher
Springer Science and Business Media LLC
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献