Abstract
Abstract
Background
The aim of this prospective clinical study was to investigate differences between virtually planned and clinically achieved implant positions in completely template-guided implant placements as a function of the tooth area, the use of alveolar ridge preservation, the implant length and diameter, and the primary implant stability.
Methods
The accuracy of 48 implants was analyzed. The implants were placed in a completely template-guided manner. The data of the planned implant positions were superimposed on the actual clinical implant positions, followed by measurements of the 3D deviations in terms of the coronal (dc) and apical distance (da), height (h), angulation (ang), and statistical analysis.
Results
The mean dc was 0.7 mm (SD: 0.3), the mean da was 1.4 mm (SD: 0.6), the mean h was 0.3 mm (SD: 0.3), and the mean ang was 4.1° (SD: 2.1). The tooth area and the use of alveolar ridge preservation had no significant effect on the results in terms of the implant positions. The implant length had a significant influence on da (p = 0.02). The implant diameter had a significant influence on ang (p = 0.04), and the primary stability had a significant influence on h (p = 0.02).
Conclusion
Template-guided implant placement offers a high degree of accuracy independent of the tooth area, the use of measures for alveolar ridge preservation or the implant configuration.
A clinical benefit is therefore present, especially from a prosthetic point of view.
Trial registration
German Clinical Trial Register and the International Clinical Trials Registry Platform of the WHO: DRKS00005978; date of registration: 11/09/2015.
Funder
Oral reconstruction foundation
Publisher
Springer Science and Business Media LLC
Cited by
11 articles.