Author:
Kiliç Mustafa,Dede Doğu Ömür,Küçükekenci Ahmet Serkan
Abstract
Abstract
Background
This study aimed to evaluate the impact of various surface treatments on the shear bond strength (SBS) of polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) polymers to indirect laboratory composite (ILC) and lithium disilicate ceramic (LDC) veneering materials.
Methods
Polymer specimens (7 × 7x2 mm) were sectioned from PEEK and PEKK discs (N = 294) and randomly allocated to 7 groups (n = 20); untreated (Cnt), plasma (Pls), 98% sulfuric acid (Sa), sandblasting with 110 µm Al2O3 (Sb), tribochemical silica coating with 110 µm silica modified Al2O3 (Tbc), Sb + Sa, Tbc + Sa. Scanning electron microscopy assessments were performed on one sample of each treatment group, and veneering materials were applied to the remaining specimens (n = 10). The specimens were subjected to the SBS test after being soaked in distilled water (24 h, 37 °C). Three-way ANOVA, independent sample t-test, and Tukey HSD test were performed for statistical analyses (α = .05).
Results
The surface treatment, polymer, veneering material types, and their interactions were significant on SBS results according to the 3-way ANOVA (p < 0.001). The SBS values of ILC veneered groups were significantly higher than LDC groups, regardless of surface treatment and polymer type (p < 0.05). The highest SBS values were obtained for Sa-applied ILC veneered PEEK (21.55 ± 1.45 MPa) and PEKK (17.04 ± 1.99 MPa) polymer groups (p < 0.05).
Conclusion
The effect of surface treatment and veneering materials may be significant on the SBS values of PAEKs. Therefore, the application parameters of surface treatments should be more specified for the applied veneering material and polymer type.
Publisher
Springer Science and Business Media LLC
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献