Author:
Lever James P.,Zdero Rad,Nousiainen Markku T.,Waddell James P.,Schemitsch Emil H.
Abstract
AbstractBackgroundA variety of techniques are available for fixation of femoral shaft fractures following total hip arthroplasty. The optimal surgical repair method still remains a point of controversy in the literature. However, few studies have quantified the performance of such repair constructs. This study biomechanically examined 3 different screw-plate and cable-plate systems for fixation of periprosthetic femoral fractures near the tip of a total hip arthroplasty.MethodsTwelve pairs of human cadaveric femurs were utilized. Each left femur was prepared for the cemented insertion of the femoral component of a total hip implant. Femoral fractures were created in the femurs and subsequently repaired with Construct A (Zimmer Cable Ready System), Construct B (AO Cable-Plate System), or Construct C (Dall-Miles Cable Grip System). Right femora served as matched intact controls. Axial, torsional, and four-point bending tests were performed to obtain stiffness values.ResultsAll repair systems showed 3.08 to 5.33 times greater axial stiffness over intact control specimens. Four-point normalized bending (0.69 to 0.85) and normalized torsional (0.55 to 0.69) stiffnesses were lower than intact controls for most comparisons. Screw-plates provided either greater or equal stiffness compared to cable-plates in almost all cases. There were no statistical differences between plating systems A, B, or C when compared to each other (p > 0.05).ConclusionsScrew-plate systems provide more optimal mechanical stability than cable-plate systems for periprosthetic femur fractures near the tip of a total hip arthroplasty.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Surgery
Reference34 articles.
1. Dennis MG, Simon JA, Kummer FJ, Koval KJ, DiCesare PE: Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques. J Arthroplasty. 2000, 15 (4): 523-528. 10.1054/arth.2000.4339.
2. Lowrey CE, Nord KD, Wilson MR, Trick LW: Periprosthetic femur fractures: a complication of rigid cylindrical reaming?. Orthop Trans. 1991, 15: 342-352.
3. Scott RD, Turner RH, Leitzes SM, Aufranc OE: Femoral fractures in conjunction with total hip replacement. J Bone Joint Surg Am. 1975, 57 (4): 494-501.
4. Stevens SS, Irish AJ, Vachtsevanos JG, Csongradi J, Beaupre GS: A biomechanical study of three wiring techniques for cerclage-plating. J Orthop Trauma. 1995, 9 (5): 381-387. 10.1097/00005131-199505000-00004.
5. Bethea JS, DeAndrade JR, Fleming LL, Lindenbaum SD, Welch RB: Proximal femoral fractures following total hip arthroplasty. Clin Orthop Rel Res. 1982, 170: 95-106.
Cited by
71 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献