Abstract
Abstract
Background
The use of X-ray as a diagnostic tool for complication and anomaly in the neonatal patient has been helpful, but the effect of radiation on newborn stands to increase their cancer risk. This study aims to determine the mean, 50th percentile (quartile 2 (Q2)), and 75th percentile (quartile 3 (Q3)) entrance surface dose (ESD) from anteroposterior (AP) chest X-ray and to compare our findings with other relevant studies. The study used calibrated thermoluminescent dosimeters (TLDs), which was positioned on the central axis of the patient. The encapsulated TLD chips were held to the patients’ body using paper tape. The mean kilovoltage peak (kVp) and milliampere seconds (mAs) used was 56.63(52–60) and 5.7 (5–6.3). The mean background TLD counts were subtracted from the exposed TLD counts and a calibration factor was applied to determine ESD.
Results
The mean ESDs of the newborn between 1 and 7, 8 and 14, 15 and 21, and 22 and 28 days were 1.09 ± 0.43, 1.15 ± 0.50, 1.19 ± 0.45, and 1.32 ± 0.47 mGy respectively. A one-way ANOVA test shows that there were no differences in the mean doses for the 4 age groups (P = 0.597). The 50th percentile for the 4 age groups was 1.07, 1.26, 1.09, and 1.29 mGy respectively, and 75th percentile were 1.41, 1.55, 1.55, and 1.69 mGy respectively. The mean effective dose (ED) in this study was 0.74 mSv, and the estimated cancer risk was 20.7 × 10−6.
Conclusion
ESD was primarily affected by the film-focus distance (FFD) and the patient field size. The ESD at 75th percentile and ED in this study was higher compared to other national and international studies. The estimated cancer risk to a newborn was below the International Commission on Radiological Protection (ICRP) limit for fatal childhood cancer (2.8 × 10−2Sv−1).
Publisher
Springer Science and Business Media LLC
Subject
Radiology Nuclear Medicine and imaging
Reference42 articles.
1. Thukral BB (2015) Problems and preferences in pediatric imaging. Indian J Radiol Imaging 25(4):359–364
2. Aramesh M, Zanganeh KA, Dehdashtian M, Malekian A, Fatahiasl J (2017) Evaluation of radiation dose received by premature neonates admitted to neonatal intensive care unit. J Clin Med Res 9:124–129
3. Hammer GP, Seidenbusch MC, Regulla DF, Spix C, Zeeb H, Schneider K et al (2011) Childhood cancer risk from conventional radiographic examinations for selected referral criteria: results from a large cohort study. Am J Roentgenol 197:1, 217–1, 223
4. Czarnecki ŁM (2015) Assessment of chest X-ray images in newborns with respiratory disorders. Kardiochirurgia i Torakochirurgia Polska 12(1):83–86
5. Roggini M, Pepino D, D’Avanzo M, Andreoli GM, Ceccanti S, Capocaccia P (2010) Respiratory distress in newborn: evaluation of chest X-rays. Minerva Pediatr 62(3 Suppl 1):217–219
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献