Validation of a size exclusion method for concomitant purification and formulation of peptide radiopharmaceuticals

Author:

Martin SebastianORCID,Wendlinger LennardORCID,Litvinenko AlexandraORCID,Faizova RadmilaORCID,Schottelius MargretORCID

Abstract

Abstract Background Both in clinical routine and in preclinical research, the established standard procedure for the final purification of radiometal-labeled peptide radiopharmaceuticals is cartridge-based reversed-phase (RP) solid phase extraction (SPE). It allows the rapid and quantitative separation of the radiolabeled peptide from hydrophilic impurities and easy integration into automated synthesis procedures. However, product elution from RP cartridges necessitates the use of organic solvents and product recovery is sometimes limited. Thus, an alternative purification method based on commercially available size exclusion cartridges was investigated. Results Since most peptide radiopharmaceuticals have a molecular weight > 1 kDa, Sephadex G10 cartridges with a molecular size cut-off of 700 Da were used for the final purification of a broad palette of 68Ga-, 64Cu- and 99mTc-labeled experimental peptide radiotracers as well as the clinically relevant ligand PSMA-617. Results (radiochemical purity (RCP, determined by ITLC), recovery from the solid support) were compared to the respective standard RP-SPE method. Generally, retention of unreacted 68Ga, 64Cu and 99mTc salts on the G10 cartridges was quantitative up to the specified elution volume (1.2 mL) for 68Ga and 99mTc and 99.6% for 64Cu. Even at increased elution volumes of 1.5-2 mL, RCPs of the eluted 68Ga- and 99mTc -radiopeptides were > 99%. For all peptides with a molecular weight ≥ 2 kDa, product recovery from the G10 cartridges was consistently > 85% upon respective adjustment of the elution volume. Product recovery was lowest for [68Ga]Ga-PSMA-617 (67%, 1.2 mL to 84%, 2 mL). The pH of the final product solution was found to be volume-dependent (1.2 mL: pH 6.3; 1.5 mL: pH 5.9; 2 mL: pH 5.5). Notably, the G10 cartridges were reused up to 20 times without compromising performance, and implementation of the method in an automated radiosynthesis procedure was successful. Conclusions Overall, size exclusion purification yielded all peptide radiopharmaceuticals in excellent radiochemical purities (> 99%) in saline within 10–12 min. Although product recovery is marginally inferior to classical SPE purifications, this method has the advantage of completely avoiding organic solvents and representing a cost-effective, easy-to-implement purification approach for automated radiotracer synthesis.

Funder

University of Lausanne

Publisher

Springer Science and Business Media LLC

Reference19 articles.

1. Agency EM. ICH guideline Q3C (R6) on impurities: guideline for residual solvents ema.europa.eu2019 [Available from: https://www.ema.europa.eu/en/documents/scientific-guideline/international-conference-harmonisation-technical-requirements-registration-pharmaceuticals-human-use_en-33.pdf.

2. Brom M, Franssen GM, Joosten L, Gotthardt M, Boerman OC. The effect of purification of Ga-68-labeled exendin on in vivo distribution. EJNMMI Res. 2016;6(1):65.

3. Chi YT, Chu PC, Chao HY, Shieh WC, Chen CC. Design of CGMP production of 18F- and 68Ga-radiopharmaceuticals. Biomed Res Int. 2014;2014:680195.

4. Decristoforo C, Knopp R, von Guggenberg E, Rupprich M, Dreger T, Hess A et al. A fully automated synthesis for the preparation of 68Ga-labelled peptides. Nucl Med Commun. 2007;28(11).

5. Gil Valenzuela MC, Mikolajczak JKM. In: Ozker K, editor. Meera Venkatesh. Technetium-99m radiopharmaceuticals: manufacture of kits. International Atomic Energy Agency; 2008.