Ultrasound at the patient’s bedside for the diagnosis and prognostication of a renal colic

Author:

Bourcier Jean-EudesORCID,Gallard Emeric,Redonnet Jean-Philippe,Abillard Morgan,Billaut Quentin,Fauque Laura,Jouanolou Anna,Garnier Didier

Abstract

Abstract Background Diagnosing a ureteral colic is sometimes difficult; however, clinicians should not fail to detect a surgical emergency. This is why diagnostic strategies depend on the imaging examinations, especially ultrasound. Prior studies have investigated the accuracy of Point of Care Ultrasound (PoCUS), but there are relatively few. This study aimed to evaluate the performance of the PoCUS in the diagnosis of renal colic. The secondary objective was to evaluate the relationship between the imaging results and the treatment performed. Methods After the clinical evaluation of patients aged > 18 years with suspected ureteral colic, the Emergency Physician (EP) trained in ultrasound performed PoCUS to conclude whether a diagnosis of “renal colic” should be made. A computed tomography (CT) examination was subsequently performed, to determine whether ureteral or bladder lithiasis was present to diagnose a ureteral colic. The patient’s management was decided according to the to degree of urinary tract dilatation, presence of perinephric fluid, size, and localization of stones. Results Of the 12 Eps in our units, seven met the training criteria for the inclusion of patients. A total of 103 patients were analyzed, and the renal colic diagnosis was retained in 85 cases after the CT examination. The accuracy of PoCUS was 91% (86; 95%) for detecting urinary tract dilatation, 83% (76; 90%) for detecting perinephric fluid, and 54% (44; 64%) for detecting lithiasis. Only high urinary tract stones with ≥ 6 mm diameter were surgically managed (p < 0.01). Conversely, distal ureteral stones with a diameter of < 6 mm were managed with medical ambulatory treatment (p < 0.05). Conclusion PoCUS is a good diagnostic tool, for renal colic, and could help reduce the requirement for the CT examinations and, hence, reduce induced radiation exposure.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3