Clinical performance of decellularized heart valves versus standard tissue conduits: a systematic review and meta-analysis

Author:

Waqanivavalagi Steve W. F. R.ORCID,Bhat Sameer,Ground Marcus B.,Milsom Paget F.,Cornish Jillian

Abstract

Abstract Background Valve replacement surgery is the definitive management strategy for patients with severe valvular disease. However, valvular conduits currently in clinical use are associated with significant limitations. Tissue-engineered (decellularized) heart valves are alternative prostheses that have demonstrated promising early results. The purpose of this systematic review and meta-analysis is to perform robust evaluation of the clinical performance of decellularized heart valves implanted in either outflow tract position, in comparison with standard tissue conduits. Methods Systematic searches were conducted in the PubMed, Scopus, and Web of Science databases for articles in which outcomes between decellularized heart valves surgically implanted within either outflow tract position of human subjects and standard tissue conduits were compared. Primary endpoints included postoperative mortality and reoperation rates. Meta-analysis was performed using a random-effects model via the Mantel-Haenszel method. Results Seventeen articles were identified, of which 16 were included in the meta-analysis. In total, 1418 patients underwent outflow tract reconstructions with decellularized heart valves and 2725 patients received standard tissue conduits. Decellularized heart valves were produced from human pulmonary valves and implanted within the right ventricular outflow tract in all cases. Lower postoperative mortality (4.7% vs. 6.1%; RR 0.94, 95% CI: 0.60–1.47; P = 0.77) and reoperation rates (4.8% vs. 7.4%; RR 0.55, 95% CI: 0.36–0.84; P = 0.0057) were observed in patients with decellularized heart valves, although only reoperation rates were statistically significant. There was no statistically significant heterogeneity between the analyzed articles (I2 = 31%, P = 0.13 and I2 = 33%, P = 0.10 respectively). Conclusions Decellularized heart valves implanted within the right ventricular outflow tract have demonstrated significantly lower reoperation rates when compared to standard tissue conduits. However, in order to allow for more accurate conclusions about the clinical performance of decellularized heart valves to be made, there need to be more high-quality studies with greater consistency in the reporting of clinical outcomes.

Funder

National Heart Foundation of New Zealand

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3