BACKGROUND
The combined anterior/posterior approach appears to be capable of reconstructing spinal stability, correcting thoracolumbar deformity, and promoting neural recovery in severe thoracolumbar fracture dislocation. However, this type of operation requires changing the body position during the procedure, resulting in a lengthy operation time. As a universal surgical robot, TINAVI robot has achieved good surgical results in clinical surgery. But to our knowledge, no reports describing TINAVI robot-assisted single lateral position anteroposterior surgery for thoracolumbar fracture dislocation.
CASE SUMMARY
We describe a case of a 16-year-old female patient with severe thoracolumbar fracture and dislocation underwent surgery assisted by the TINAVI robot. A one-stage combined anterior and posterior operation was performed on a severe thoracolumbar fracture dislocation using the TINAVI robot, and the operation was completed in right lateral position.
CONCLUSION
The TINAVI robot-assisted one-stage anterior and posterior surgery in right lateral position for severe thoracolumbar fracture and dislocation is both safe and effective.