Prototype single-balloon enteroscopy with passive bending and high force transmission improves depth of insertion in the small intestine

Author:

Morita YasuhiroORCID,Bamba ShigekiORCID,Inatomi OsamuORCID,Takahashi KenichiroORCID,Imai TakayukiORCID,Murata MasakiORCID,Ohno MasashiORCID,Sasaki MasayaORCID,Tsujikawa TomoyukiORCID,Andoh AkiraORCID

Abstract

Background/Aims: We retrospectively analyzed Crohn’s disease (CD) patients with small intestinal strictures who underwent single-balloon enteroscopy (SBE) to ascertain whether prototype SBEs with a passive bending mechanism and high force transmission insertion tube had better insertability in the small intestine than a conventional SBE.Methods: Among 253 CD patients who underwent SBE, we identified 94 CD patients who had undergone attempted endoscopic balloon dilatation (EBD) for small intestinal stenosis for inclusion in this study. We analyzed whether the type of scope used for their initial procedure affected the cumulative surgery-free rate. For the insertability analysis, patients who underwent SBE at least twice were divided into 3 groups according to the type of scope used: conventional SBE only, prototype SBE only, and both conventional and prototype SBEs. For each group, depth of insertion, procedure time, and number of EBDs were compared in the same patient at different time points.Results: The success rate of EBD was 88.3%. The 5- and 10-year cumulative surgery-free rate was 75.7% and 72.8%, respectively. Cox regression analysis indicated that the factors contributing to surgery were long stricture (≥2 cm), EBD failure, and elevated Crohn’s Disease Activity Index, but not the type of scope used for EBD. The prototype SBEs significantly improved the depth of insertion (<i>P</i>=0.03, Wilcoxon’s signed-rank test).Conclusions: In CD patients with small intestinal stenosis, the prototype SBEs with a passive bending mechanism and high force transmission insertion tube did not improve long-term EBD outcome but did improve deep insertability. (Clinical Trial Registration No. UMIN000037102)

Publisher

Korean Association for the Study of Intestinal Diseases

Subject

Gastroenterology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3