Abstract

Resting beat-to-beat blood pressure variability is a powerful predictor of cardiovascular events and end-organ damage. However, its underlying mechanisms remain unknown. Herein, we tested the hypothesis that a potentiation of GABAergic synaptic transmission by diazepam would acutely increase resting beat-to-beat blood pressure variability. In 40 (17 females) young, normotensive subjects, resting beat-to-beat blood pressure (finger photoplethysmography) was continuously measured for 5–10 min, 60 min after the oral administration of either diazepam (10 mg) or placebo. The experiments were conducted in a randomized, double-blinded, and placebo-controlled design. Stroke volume was estimated from the blood pressure waveform (ModelFlow) permitting the calculation of cardiac output and total peripheral resistance. Direct recordings of muscle sympathetic nerve activity (MSNA, microneurography) were obtained in a subset of subjects ( n = 13), and spontaneous cardiac and sympathetic baroreflex sensitivity were calculated. Compared with placebo, diazepam significantly increased the standard deviation of systolic blood pressure (4.7 ± 1.4 vs. 5.7 ± 1.5 mmHg, P = 0.001), diastolic blood pressure (3.8 ± 1.2 vs. 4.5 ± 1.2 mmHg, P = 0.007), and mean blood pressure (3.8 ± 1.1 vs. 4.5 ± 1.1 mmHg, P = 0.002), as well as cardiac output (469 ± 149 vs. 626 ± 259 mL/min, P < 0.001) and total peripheral resistance (1.0 ± 0.3 vs. 1.4 ± 0.6 mmHg/L/min, P < 0.001). Similar results were found using different indices of variability. Furthermore, diazepam reduced MSNA (placebo: 22 ± 6 vs. diazepam: 18 ± 8 bursts/min, P = 0.025) without affecting the arterial baroreflex control of heart rate (placebo: 18.6 ± 6.7 vs. diazepam: 18.8 ± 7.0 ms/mmHg, P = 0.87) and MSNA (placebo: −3.6 ± 1.2 vs. diazepam: −3.4 ± 1.5 bursts/100 Hb/mmHg, P = 0.55). Importantly, these findings were not impacted by biological sex. We conclude that GABAA receptors modulate resting beat-to-beat blood pressure variability in young adults.

Funder

Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada

MCTI | Conselho Nacional de Desenvolvimento Cient�fico e Tecnol�gico

Canada Foundation for Innovation

Ontario Ministry of Research, Innovation and Science

Ontario Ministry of Economic Development, Job Creation and Trade

American Physiological Society

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3