Cardiovascular and respiratory responses to slow ramp carotid sinus pressures in the dog

Author:

Jung R.1,Katona P. G.1

Affiliation:

1. Department of Biomedical Engineering, School of Engineering, Case Western Reserve University, Cleveland, Ohio 44106.

Abstract

The respiratory and mean arterial pressure (MAP) responses to slow ramp pressure stimulation of carotid baroreceptors were compared in pentobarbital-anesthetized vagotomized dogs breathing 100% O2. Carotid sinus pressure (CSP) was raised from 50 (control) to 220 mmHg and then returned to control as linear ramps (+/- 1 mmHg/s) in isolated sinuses. MAP, heart rate (HR), ventilation (VE), frequency (f), and tidal volume (VT) were expressed as percent of control. The maximum difference between responses to positive and negative ramps at a given CSP (MAX) and the average difference (AVG) served as indicators of the hysteresis for each response. In 27 dogs MAP changed monotonically with varying CSP with insignificant (P = 0.27, MAX) or barely significant (P = 0.03, AVG) hysteresis, monotonic function being one that is continuously nondecreasing or continuously nonincreasing. Similar responses were obtained for HR. VE decreased as CSP increased, but the change was not monotonic. During negative ramp, VE increased back to control with an overshoot. Hysteresis for VE was pronounced (P less than 0.0001, both measures). The VE response was primarily determined by f; VT increased with CSP. To eliminate secondary respiratory effects due to alterations in MAP, in seven dogs similar experiments were performed after ganglionic blockade with hexamethonium. Hysteresis in VE and f persisted. To assess the role of changing arterial PCO2 (PaCO2) on VE, the CSP was held constant (after a ramp rise) at 140, 150, or 180 mmHg before reducing it at -1 mmHg/s to 50 mmHg; however, a significant hysteresis in VE was still observed. Further experiments, to eliminate secondary reflexes due to altered PaCO2, were performed in seven dogs after ganglionic blockade and paralysis with Flaxedil, with phrenic nerve activity as an indicator of (“neural”) respiration. The hysteresis in VE and f were no longer significant. In summary, the results indicate that 1) slow ramp carotid baroreceptor stimulation elicits both VE and cardiovascular responses, the VE response showing a dramatically higher hysteresis than the cardiovascular responses; 2) the ventilatory hysteresis is partially explained by the secondary changes in PaCO2 and perhaps by cardiovascular variables; and 3) the central processing of the baroventilatory reflex appears to be rate sensitive at a slower rate of pressure change than that which causes rate sensitivity in the baropressure reflex.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3