Affiliation:
1. Department of Medicine, Postgraduate Medical School, Hammersmith Hospital, London, England
Abstract
Carbon dioxide labeled with oxygen 15 has been used to measure regional blood flow in the lung by counting over the chest during a short breath-holding period following a single breath of the gas. This gas has been found to exhibit different physiological behavior from carbon-11-labeled CO2. For example, the clearance rates of the oxygen-labeled gas are about twice as fast as those of carbon-labeled CO2. Measurements on alveolar gas expired immediately after inspiration of active gas show that the oxygen-labeled gas disappears from the alveoli about ten times faster than its carbon-labeled counterpart. In addition, if venous blood is drawn shortly after a breath of oxygen-labeled CO2, the activity cannot be removed from the blood by adding acid and shaking under vacuum, whereas the expected loss of activity occurs for carbon-labeled gas. These apparent discrepancies can be explained by exchange between the oxygen atoms of water and bicarbonate after the gas has been taken up by the blood. In vitro measurements show that the uptake of oxygen-labeled CO2 into blood can be reduced by adding carbonic anhydrase inhibitor. The results affect the interpretation of the clearance rates of other radioactive gases in the lung. Submitted on December 7, 1960
Publisher
American Physiological Society
Subject
Physiology (medical),Physiology
Cited by
88 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献