Affiliation:
1. University of Georgia, College of Veterinary Medicine, Department of Large Animal Medicine, Athens 30602.
Abstract
A pump-perfused extracorporeal digital preparation was used to evaluate blood flow, arterial pressure, venous pressure, isogravimetric capillary filtration coefficient, capillary pressure, and vascular compliance in six normal horses. From these data, pre- and postcapillary resistances and pre- and postcapillary resistance ratios were determined. Vascular and tissue oncotic pressures were estimated from plasma and lymph protein concentrations, respectively. By use of the collected and calculated data, tissue pressure in the digit was calculated using the Starling equation. In the isolated equine digit, isogravimetric capillary pressure averaged 36.7 mmHg, plasma and lymph oncotic pressures averaged aged 19.12 and 6.6 mmHg, respectively, interstitial fluid pressure averaged 25.6 mmHg, and the capillary filtration coefficient averaged 0.0013 ml.min-1.mm-1.100 g-1. Our results indicate that digital capillary pressure in the laterally recumbent horse is much higher than in analogous tissues in other species such as dog and human. However, the potential edemagenic effects of this high digital capillary pressure are opposed by at least two mechanisms: 1) a high tissue pressure and 2) a low microvascular surface area for fluid exchange and/or a low microvascular permeability to filtered fluid.
Publisher
American Physiological Society
Subject
Physiology (medical),Physiology
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献