Cadaver validation of skeletal muscle measurement by magnetic resonance imaging and computerized tomography

Author:

Mitsiopoulos N.1,Baumgartner R. N.2,Heymsfield S. B.3,Lyons W.4,Gallagher D.3,Ross R.1

Affiliation:

1. School of Physical and Health Education, Queen’s University, Kingston, Ontario, Canada K7L 3N6;

2. Clinical Nutrition Program, University of New Mexico School of Medicine, Albuquerque, New Mexico 87131;

3. St-Luke’s-Roosevelt Hospital, Columbia University, College of Physicians and Surgeons, New York, New York 10025; and

4. Department of Anatomy, Queen’s University, Kingston, Ontario, Canada K7L 3N6

Abstract

Magnetic resonance imaging (MRI) and computerized tomography (CT) are promising reference methods for quantifying whole body and regional skeletal muscle mass. Earlier MRI and CT validation studies used data-acquisition techniques and data-analysis procedures now outdated, evaluated anatomic rather than adipose tissue-free skeletal muscle (ATFSM), studied only the relatively large thigh, or found unduly large estimation errors. The aim of the present study was to compare arm and leg ATFSM cross-sectional area estimates (cm2) by using standard MRI and CT acquisition and image-analysis methods with corresponding cadaver estimates. A second objective was to validate MRI and CT measurements of adipose tissue embedded within muscle (interstitial adipose tissue) and surrounding muscle (subcutaneous adipose tissue). ATFSM area ( n = 119) by MRI [38.9 ± 22.3 (SD) cm2], CT (39.7 ± 22.8 cm2), and cadaver (39.5 ± 23.0 cm2) were not different ( P > 0.001), and both MRI and CT estimates of ATFSM were highly correlated with corresponding cadaver values [MRI: r = 0.99, SE of estimate (SEE) 3.9 cm2, P < 0.001; and CT: r = 0.99, SEE = 3.8 cm2, P < 0.001]. Similarly good results were observed between MRI- and CT-measured vs. cadaver-measured interstitial and subcutaneous adipose tissue. For MRI-ATFSM the intraobserver correlation for duplicate measurements in vivo was 0.99 [SEE = 8.7 cm2(2.9%), P < 0.001]. These findings strongly support the use of MRI and CT as reference methods for appendicular skeletal muscle, interstitial and subcutaneous adipose tissue measurement in vivo.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3