Hormone pulsatility discrimination via coarse and short time sampling

Author:

Pincus Steven M.1,Hartman Mark L.2,Roelfsema Ferdinand3,Thorner Michael O.2,Veldhuis Johannes D.2

Affiliation:

1. Guilford, Connecticut 06437;

2. Department of Internal Medicine, National Science Foundation Center for Biological Timing, University of Virginia, Charlottesville, Virginia 22908;

3. Department of Endocrinology, Leiden University Medical Center, Leiden 2333AA, The Netherlands

Abstract

Pulsatile hormonal secretion is a ubiquitous finding in endocrinology. However, typical protocols employed to generate data sets suitable for “pulsatility analysis” have required 60–300 samples, rendering such studies largely research methodologies, due primarily to considerable assay expense. One successful mathematical strategy in calibrating changes in pulsatility modalities is approximate entropy (ApEn), a quantification of sequential irregularity. Given the degree of differences between ApEn values in pathophysiological subjects vs. healthy controls reported in several recent studies, we queried to what extent coarser (less frequent) and shorter duration time sampling would still retain significant ApEn differences between clinically distinct cohorts. Accordingly, we reanalyzed data from two studies of 24-h profiles of healthy vs. tumoral hormone secretion: 1) growth hormone comparisons of normal subjects vs. acromegalics, originally sampled every 5 min; and 2) ACTH and cortisol comparisons of normal subjects vs. Cushing's disease patients, originally sampled every 10 min. By multiple statistical analyses, we consistently and highly significantly ( P < 0.0001) established that serum concentration patterns in tumor patients are more irregular than those of controls, with high sensitivity and specificity, even at very coarse (e.g., 60 min) sampling regimens and over relatively short (2–4 h) time intervals. The consistency of these findings suggests a broadly based utility of such shorter and/or coarser sampling methodologies. Substantial reduction in sampling requirements holds the potential to move analysis of pulsatile hormone release from a primarily research tool to a clinically applicable protocol, in appropriate diagnostic and therapeutic contexts.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology,Endocrinology, Diabetes and Metabolism

Cited by 115 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3