Fluorescent microsphere method is suitable for chronic bone blood flow measurement: a long-term study after meniscectomy in rabbits

Author:

Anetzberger H.,Thein E.,Löffler G.,Messmer K.

Abstract

The fluorescent microsphere (FM) method is considered a reliable technique to determine regional bone blood flow (RBBF) in acute experiments. In this study, we verified the accuracy and validity of this technique for measurement of RBBF in a long-term experiment and examined RBBF after meniscectomy. Twenty-four anesthetized female New Zealand white rabbits (3 groups, each n = 8) received consecutive left ventricular injections of FM in defined time intervals after meniscectomy: group 1 from preoperation to 3 wk postoperation; group 2 from 3 to 7 wk postoperation; and group 3 from 7 to 11 wk postoperation. To test the precision of the FM method, two FM species were injected simultaneously at the first and last measurement. After the experiment, humeri, femora, tibiae, and reference organs (kidney, lung, brain) were removed and dissected according to standardized protocols. Fluorescence was determined in each reference blood and tissue sample, and blood flow values were calculated. Blood flow in kidney, lung, and brain revealed no significant difference between right and left side and remained unchanged during the observation period, thus excluding errors due to shunting and dislodging of spheres in our experiments. Comparison of relative bone blood flow values obtained by simultaneously injected FM showed an excellent correlation at the first and last injection, indicating valid RBBF measurements in long-term experiments. We found a significant increase in RBBF 3 wk after meniscectomy in the right tibial condyles compared with the nonoperated left side. Similar changes were found in the femoral condyles. RBBF in other regions of tibia, femur, and humerus revealed no significant differences between right- and left-sided bone samples of the same region. Our results demonstrate that the FM method is valid for measuring RBBF in long-term experiments. In addition, we were able to demonstrate that meniscectomy leads to an increase in RBBF in the tibial condyles at a very early stage. This increase might be caused by stress-induced alterations of the subchondral bone.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3