Effective distributed compliance of the canine descending aorta estimated by modified T-tube model

Author:

Burattini R.1,Campbell K. B.1

Affiliation:

1. Department of Electronics and Automatica, University of Ancona, Italy.

Abstract

To estimate descending thoracic aortic compliance in anesthetized open-chest dogs, a modified T-tube arterial model was used. This model consists of two uniform and lossless elastic tubes, one representing arteries going toward the head and upper limbs and the other (body tube) representing descending aortic circulation to the trunk and lower limbs. Each tube terminates with a generalized first-order low-pass filter load. Pressure and flow in the ascending aorta and flow in the upper descending aorta were measured and used to estimate model parameters. Using the estimated model parameters, we calculated the pressure waveshape at the termination of the body tube. Comparison of this model-predicted pressure with pressure measured in the abdominal aorta near the origin of renal arteries suggested that the end of the body tube (effective reflecting site of the body circulation) corresponds to this major branching site of the abdominal aorta. To calculate the length of the body tube, we used aortic pulse wave velocity estimated from the measurements of pressure in ascending and abdominal aorta. Calculated body tube length averaged 30.3 +/- 2.8 cm and approximated the measured length (30.6 +/- 3.0 cm) of the aorta from the arch to the region of the origin of renal arteries. Compliance of the body tube averaged 123 +/- 20 x 10(-6) g-1.cm4.s2 and was interpreted as the descending thoracic aortic compliance. The ratio of this compliance to the body tube length gave an estimate of the effective distributed compliance, i.e., the compliance per unit length that would be observed in the absence of tapering. This ratio averaged 4.10 +/- 0.86 x 10(-6) g-1.cm3.s2 and fell in between the values of local aortic compliance independently estimated along the descending thoracic aorta from measurements of pressure and diameter. Thus tube compliance resulted in a physically identifiable property. This property was contrasted with the ill-defined effective compliances of the terminal loads.

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

Cited by 22 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3