Cyclohexanone contamination from extracorporeal circuits impairs cardiovascular function

Author:

Thompson-Torgerson Caitlin S.,Champion Hunter C.,Santhanam Lakshmi,Harris Z. Leah,Shoukas Artin A.

Abstract

Extracorporeal circulation provides critical life support in the face of cardiopulmonary or renal failure, but it also introduces a host of unique morbidities characterized by edema formation, cardiac insufficiency, autonomic dysfunction, and altered vasomotor function. We tested the hypothesis that cyclohexanone (CHX), a solvent used in production of extracorporeal circuits and intravenous (IV) bags, leaches into the contained fluids and can replicate these clinical morbidities. Crystalloid fluid samples from circuits and IV bags were analyzed by gas chromatography-mass spectrometry to provide a range of clinical CHX exposure levels, revealing CHX contamination of sampled fluids (9.63–3,694 μg/l). In vivo rat studies were conducted ( n = 49) to investigate the effects of a bolus IV infusion of CHX vs. saline alone on cardiovascular function, baroreflex responsiveness, and edema formation. Cardiovascular function was evaluated by cardiac output, heart rate, stroke volume, vascular resistance, arterial pressure, and ventricular contractility. Baroreflex function was assessed by mean femoral arterial pressure responses to bilateral carotid occlusion. Edema formation was assessed by the ratio of wet to dry organ weights for lungs, liver, kidneys, and skin. CHX infusion led to systemic hypotension; pulmonary hypertension; depressed contractility, heart rate, stroke volume, and cardiac output; and elevated vascular resistance ( P < 0.05). Mean arterial pressure responsiveness to carotid occlusion was dampened after CHX infusion (from +17.25 ± 1.8 to +5.61 ± 3.2 mmHg; P < 0.05). CHX infusion led to significantly higher wet-to-dry weight ratios vs. saline only (3.8 ± 0.06 vs. 3.5 ± 0.05; P < 0.05). CHX can reproduce clinical cardiovascular, neurological, and edema morbidities associated with extracorporeal circulatory treatment.

Publisher

American Physiological Society

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Physiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3