Research on Data Acquisition and Regulation Methods of Basement Flashing Pressure Relief System Based on Digital Technology
Author:
Zhao Shixiao1, Shi Wei2, Zhang Lei1, Zhang Yan1, Zhang Hailiang1
Affiliation:
1. 1 China Construction First Group Corporation Limited , Beijing , , China . 2. 2 Kunming Prospecting Design Institute Of China Nonferrous Metals Industry Co., Ltd , Kunming , Yunnan , , China .
Abstract
Abstract
This study utilizes digital technology to monitor water pressure changes within basement flashings, facilitating targeted drainage operations. By implementing an active water discharge method, drainage holes are strategically placed around or beneath basements to decompress and reduce water levels, thereby alleviating hydrostatic pressure on underground structures. This approach helps prevent basement uplift. The paper addresses challenges such as high energy consumption and ample data storage in long-term monitoring, introducing an acceleration trigger module and a data correction algorithm based on an enhanced BP neural network. A WOA-BP neural network model was developed using historical data to monitor water pressure efficiently. Our findings indicate that at 0.076MPa, flashing connections begin to fail, progressing to shear damage at 0.085MPa. Consequently, to preserve basement integrity, it is crucial to activate complete drainage when monitored pressure exceeds 0.045MPa to maintain pressures below the critical threshold of 0.076MPa.
Publisher
Walter de Gruyter GmbH
Reference20 articles.
1. Adam, H., Grisel, R., Greg, W., & Mike, M. (2017). Maximizing infiltration rates by removing suspended solids: results of demonstration testing of riverbed filtration in orange county, california. Water, 9(2), 119. 2. Sun, H., Zhang, J., Zhao, G., & Wang, H. (2021). Tunnel behaviour caused by basement excavation in clay. Geofluids. 3. Tankersley, M. D., Horgan, H. J., Siddoway, C. S., Tontini, F. C., & Tinto, K. J. (2022). Basement topography and sediment thickness beneath antarctica’s ross ice shelf. Geophysical Research Letters(10), 49. 4. Duran, B., Tunaboyu, O., & zgür Avar. (2020). Structural failure evaluation of a substandard rc building due to basement story short-column damage. Journal of Performance of Constructed Facilities(4), 34. 5. Bing, Z., Xian-Fang, S., Ying-Hua, Z., Dong-Mei, H., Chang-Yuan, T., & Li-Hu, Y., et al. (2017). The renewability and quality of shallow groundwater in sanjiang and songnen plain, northeast china. Journal of Integrative Agriculture, 16(001), 229-238.
|
|