Thermally assisted OSL: A potent tool for improvement in minimum detectable dose and extension of dose range of Al2O3:C

Author:

Soni Anuj1,Mishra Devesh1,Bhatt Bhuwan2,Gupta Shiv3,Rawat Narendra1,Kulkarni Mukund1,Sharma Devanand1

Affiliation:

1. Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Trombay, Mumbai, India, 400085

2. 2DST Fellow, C/o Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Trombay, Mumbai, India, 400085

3. Technical Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai, India, 400085

Abstract

Abstract The influence of electron-phonon interaction on the shape of the optically stimulated luminescence decay curve of Al2O3:C has been studied using thermally assisted optically stimulated luminescence (TA-OSL). The minimum detectable dose (MDD) of a phosphor depends on the standard deviation of the background signal which affects the signal-to-noise ratio. The standard deviation of the background signal reduces at lower stimulation light intensity while the readout time increases. Further, measurement at higher temperature enhances the OSL signal with faster decay due to the temperature dependence of photo-ionization cross-section. To achieve the same decay constant and more signal, the temperature of measurement was raised. As a result of lowering the stimulation in-tensity at higher temperature (85°C) the overall MDD of α-Al2O3:C was found to improve by 1.8 times. For extension of dose linearity in higher range, deeper traps were studied by simultaneous application of CW-OSL and thermal stimulation up to 400°C, using a linear heating rate of 4K/s. By using this method, two well defined peaks at 121°C and 232°C were observed. These TA-OSL peaks have been correlated with two deeper defects which can be thermally bleached at 650°C and 900°C respectively. These deeper defects are stable up to 500°C, so they can store absorbed dose information even if the sample is inadvertently exposed to light or heat. The dose vs. TA-OSL response from deep traps of α-Al2O3:C was found to be linear up to 10 kGy, thus extending its application for high dose dosimetry.

Publisher

Walter de Gruyter GmbH

Subject

Earth and Planetary Sciences (miscellaneous)

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3