Cytotoxicity evaluation of different clear aligner materials using MTT analysis

Author:

Ozkan Esra Cifci1,Gok Gulay Dumanli1,Ordueri Nazli Ece2,Elgun Tugba3

Affiliation:

1. Biruni University, Faculty of Dentistry , Department of Orthodontics , Istanbul , Turkey

2. Biruni University, Faculty of Medicine , Department of Histology and Embriology , Istanbul , Turkey

3. Biruni University, Faculty of Medicine , Department of Medical Biology , Istanbul , Turkey

Abstract

Abstract Backround: The in vitro cytotoxic effects of six different clear aligner materials were evaluated using the MTT analysis. Methods: The clear aligner material samples [Duran (ScheuDental GmbH, Iserlohn, Germany), Zendura-Flx (Bay Materials LLC, Fremont, CA, USA), Taglus (Laxmi Dental Export Pvt. Ltd, Mumbai, India), Smart Track (Align Technology, San Jose, CA, USA), Zendura (Bay Materials LLC, Fremont, CA, USA), Essix C + (Essix® (Raintree Essix, Inc., 4001 Division St, Metairie, LA-USA)] were initially kept in a saline solution in airtight test tubes for 8 weeks at 37°C. According to the recommended ISO standards, the weights of the samples were divided by the volumes of the dilutions in the ratio of 0.1 g/ml. To evaluate the cytotoxicity of the samples, an MTT analysis was performed using a human gingival fibroblast cell line (HGF). To analyse the data, the Kruskal– Wallis test was applied (a=0.05). Results: Zendura was the most cytotoxic material resulting in 67.3 ± 16.20% cell viability, followed by Smart Track with 87.6 ± 5.53% cell viability. While Duran, Essix C + had 92.6 ± 26.34% and 94.9 ± 8.54% cell viability, Zendura-Flx, Taglus had 106.9 ± 12.76% and 113.183 ± 7.45% cell viability, respectively. Conclusion: While Zendura and Smart Track showed mild cytotoxicity, other materials showed greater cell viabilities. According to the ISO standards, the clinical use of each brand of aligners, except Zendura, may be considered reliable. Taking into account standard deviation, Zendura and Duran should be used with caution. The suppliers of aligners should adhere to the manufacturer’s recommendations since an increase in ion release might arise from material wear.

Publisher

Walter de Gruyter GmbH

Subject

Orthodontics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3