Coronary Angioplasty and Stenting in Acute Coronary Syndromes Using Very Low Contrast Volume and Radiation Dosage Improves Renal and Cardiovascular Outcomes

Author:

Arokiaraj Mark Christopher1

Affiliation:

1. Cardiology, Pondicherry Institute of Medical Sciences , Puducherry , India

Abstract

Abstract Aim: To demonstrate that in patients with acute coronary syndrome (ACS), using Cordis 6F Infiniti diagnostic catheters for angioplasty may represent a safe alternative associated with lower contrast volume and radiation dosage, improving cardiovascular and renal outcomes. Material and Methods: In 1,800 patients with ACS (2,331 lesions/2,603 stents), angioplasty was performed with Cordis 6F Infiniti Thrulumen diagnostic catheters. Primary angioplasty was performed in 545 cases, and only balloon angioplasty in 67 patients. All procedures were performed through the femoral route, and switch-over to the radial route was made in 5 cases due to associated aortic/iliac obstructive lesions. Iodixanol was used in 76% of cases, and tirofiban in 99% of cases with adjusted dosages based on creatinine values. The mean contrast volume used per patient was 28 mL (± 6 mL) including the angiogram prior to the angioplasty. Results: The median fluoroscopy time was 4.4 min (IQR 3–6.8), the mean fluoroscopy time was 5.59 min (± 0.28), the median dose-area product or kerma-area product was 1,507 µGym2 (IQR 918–2,611), median total or cumulative dose including backscatter was 2,702 µGym2 (IQR 1,805–4,217), and the median cumulative skin dose was 468 mGy (IQR 296–722). Groin hematoma was seen in 7 cases, proximal mild edge dissection in the deployed stent in 3 cases, and acute in-hospital stent thrombosis in 7 cases. In total, 33 deaths were registered and 19 of these patients had cardiogenic shock, of which 11 subjects were late presenters. Three patients died after discharge due to possible acute stent thrombosis. Conclusions: Angioplasty and stenting can be performed safely in patients with acute coronary syndromes using Cordis 6F diagnostic catheters. The procedure was associated with a very low volume of contrast and radiation dose, leading to improved clinical outcomes..

Publisher

Walter de Gruyter GmbH

Subject

Automotive Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3