Abstract

Abstract Background 13C-mixed triglyceride breath test (13C-MTGT) is a non-invasive test for the detection of moderate and severe pancreatic exocrine insufficiency (PEI), but it requires prolonged breath sampling. The aim of this study was to determine the diagnostic power of abbreviated 13C-MTGT in detecting PEI in patients after subtotal and total gastrectomy performed due to gastric cancer. Subjects and methods This cross-sectional observational study included 3 groups of subjects; healthy controls, patients with subtotal and patients with total gastrectomy. Demographic and clinical data of patients were collected. Stool samples to determine faecal elastase (Fe-1) and chymotrypsin were collected and measured by ELISA. All subjects performed 5-hour 13C-MTGT breath test. The concentration and relative content of 13C in exhaled air was measured by isotope ratio mass spectrometer (IRMS). PEI was confirmed as values of 13C-exhalation < 26.8% after 5 hours. Results Overall, 65 participants were included into analysis, 22 having PEI (n = 11 after subtotal and n = 11 after total gastrectomy, both performed for gastric cancer). 13C-MTGT breath test showed difference in percent of exhaled 13C between PEI and non-PEI patients already after 60 minutes (p = 0.034). Receiver operating characteristic (ROC) curve analysis showed that cut-off value of 13.74% after 150 minutes is showing equivalent diagnostic power to the longer test with sensitivity and specificity both above 90% for the exclusion of PEI in patients after subtotal and/or total gastrectomy. Conclusions In this study abbreviated 13C-MTGT test could be shortened from 5 to 2.5 hours without decrease in its diagnostic accuracy for detection of PEI in patients with subtotal or total gastrectomy performed for gastric cancer. This allows significant time savings in the diagnostics of PEI in this subgroup of patients.

Publisher

Walter de Gruyter GmbH

Subject

Radiology, Nuclear Medicine and imaging,Oncology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3