Anatomical landmarks and skin markers are not reliable for accurate labeling of thoracic vertebrae on MRI

Author:

Shabshin Nogah12,Schweitzer Mark E.3,Carrino John A.4

Affiliation:

1. Department of Diagnostic Imaging, Chaim Sheba Medical Center, Tel-HaShomer, Israel

2. Department of Radiology, Hospital of University of Pennsylvania, Philadelphia, PA, USA

3. Department of Diagnostic Imaging, Ottawa Hospital and University of Ottawa, Ottawa, Canada

4. Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, USA

Abstract

Background: Numbering of the thoracic spine on MRI can be tedious if C2 and L5–S1 are not included and may lead to errors in lesion level. Purpose: To determine whether anatomic landmarks or external markers are reliable as an aid for accurate numbering of thoracic vertebrae on MRI. Material and Methods: Sixty-seven thoracic spine MR studies of 67 patients (30 males, 37 females, age range 18–83 years) were studied, composed of 52 consecutive MR studies and an additional 15 MRI in which vitamin E markers were placed over the skin. In the 52 thoracic MR examinations potential numbering aids such as the level of the sternal apex, pulmonary artery, aortic arch, and osseous or disc abnormalities were numbered on both cervical localizer (standard of reference) and thoracic sagittal images. The additional 15 examinations in which vitamin E markers were placed over the skin were evaluated for consistency in the level of the markers on different sequences in the same exam. Results: The sternal apex level ranged from T2 to T5 [T3 in 28/51 patients (55%), T2 in 10/51 (20%)]. The aortic arch level ranged from T2 to T4 [T4 in 18/48 (38%) and T3 in 17 (35%)]. Pulmonary artery level ranged from T4 to T6–7 disc [T5 in 20/52 patients (38%) and T6 in 14/52 (27%)]. In 3 of 12 patients who had abnormalities in a vertebral body or disc as definite point reference, the non-localizer image mislabeled the level. In 11/15 (73%) patients with vitamin E markers that were placed over the upper thoracic spine, the results showed consistency in the level of the markers in relation to the reference points or consistent inter-marker gap between the sequences. Conclusion: There are only two reliable ways to accurately define the levels if no landmarking feature is available on the magnet. The first is by including C2 in the thoracic sequence of a diagnostic quality, and the second is by using an abnormality in the discs or vertebral bodies as a point of reference.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3