Affiliation:
1. Shiraz University, Shiraz, Iran (the Islamic Republic of)
2. Shiraz University of Medical Sciences, Shiraz, Iran (the Islamic Republic of)
Abstract
AbstractThe cumulative activity map estimation are essential tools for patient specific dosimetry with high accuracy, which is estimated using biokinetic models instead of patient dynamic data or the number of static PET scans, owing to economical and time-consuming points of view. In the era of deep learning applications in medicine, the pix-to-pix (p2 p) GAN neural networks play a significant role in image translation between imaging modalities. In this pilot study, we extended the p2 p GAN networks to generate PET images of patients at different times according to a 60 min scan time after the injection of F-18 FDG. In this regard, the study was conducted in two sections: phantom and patient studies. In the phantom study section, the SSIM, PSNR, and MSE metric results of the generated images varied from 0.98–0.99, 31–34 and 1–2 respectively and the fine-tuned Resnet-50 network classified the different timing images with high performance. In the patient study, these values varied from 0.88–0.93, 36–41 and 1.7–2.2, respectively and the classification network classified the generated images in the true group with high accuracy. The results of phantom studies showed high values of evaluation metrics owing to ideal image quality conditions. However, in the patient study, promising results were achieved which showed that the image quality and training data number affected the network performance. This study aims to assess the feasibility of p2 p GAN network application for different timing image generation.
Subject
Radiology, Nuclear Medicine and imaging,General Medicine
Reference29 articles.
1. PET/CT today and tomorrow;D W Townsend;Journal of Nuclear Medicine,2004
2. Internal dosimetry in F-18 FDG PET examinations based on long-time-measured organ activities using total-body PET/CT: does it make any difference from a short-time measurement?;P Hu;EJNMMI physics,2021
3. Normal values for 18F-FDG uptake in organs and tissues measured by dynamic whole body multiparametric FDG PET in 126 patients;A H Dias;EJNMMI research,2022
4. Radiation dose to patients from radiopharmaceuticals: (Addendum 2 to ICRP Publication 53) ICRP Publication 80 Approved by the Commission in September 1997;J Valentin;Annals of the ICRP,1998
5. PET kinetic analysis compartmental model;H Watabe;Annals of nuclear medicine,2006
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献