Correct and Incorrect Recommendations for or against Fine Needle Biopsies of Hypofunctioning Thyroid Nodules: Performance of Different Ultrasound-based Risk Stratification Systems

Author:

Petersen Manuela1,Schenke Simone A.23,Seifert Philipp4,Stahl Alexander R.,Görges Rainer5,Grunert Michael67,Klemenz Burkhard6,Kreissl Michael C.38,Zimny Michael9

Affiliation:

1. Department of General, Visceral, Vascular and Transplant Surgery, University Hospital Magdeburg, Germany

2. Department and Institute of Nuclear Medicine, Hospital Bayreuth, Germany

3. Division of Nuclear Medicine, Department of Radiology and Nuclear Medicine, University Hospital Magdeburg, Germany

4. Clinic of Nuclear Medicine, University Hospital Jena, Germany

5. Clinic for Nuclear Medicine, University Hospital Essen, Germany

6. Department of Nuclear Medicine, German Armed Forces Hospital Ulm, Germany

7. Department of Nuclear Medicine, University Hospital Ulm, Germany

8. Research Campus STIMULATE, Otto-von-Guericke University, Magdeburg, Germany

9. Institute for Nuclear Medicine Hanau, Germany

Abstract

Abstract Purpose To evaluate the recommendations for or against fine needle biopsy (FNB) of hypofunctioning thyroid nodules (TNs) using of five different Ultrasound (US) -based risk stratification systems (RSSs). Methods German multicenter study with 563 TNs (≥ 10 mm) in 534 patients who underwent thyroid US and surgery. All TNs were evaluated with ACR TI-RADS, EU-TIRADS, ATA, K-TIRADS 2016 and modified K-TIRADS 2021. A correct recommendation was defined as: malignant TN with recommendation for FNB (appropriate) or benign TN without recommendation for FNB (avoided). An incorrect recommendation was defined as: malignant TN without recommendation for FNB (missed) or benign TN with recommendation for FNB (unnecessary). Results ACR TI-RADS demonstrated the highest rate of correct (42.3 %) and lowest rate of incorrect recommendations (57.7 %). The other RRSs showed similar results for correct (26.5 %–35.7 %) and incorrect (64.3 %–73.5 %) recommendations. ACR TI-RADS demonstrated the lowest rate of unnecessary (73.4 %) and the highest rate of appropriate (26.6 %) FNB recommendation. For other RSSs, the rates of unnecessary and appropriate FNB were between 75.2 %–77.1 % and 22.9 %–24.8 %. The lowest rate of missed FNB (14.7 %) and the highest rate of avoided FNB (85.3 %) was found for ACR TI-RADS. For the other RSSs, the rates of missed and avoided FNB were between 17.8 %–26.9 % and 73.1 %–82.2 %. When the size cutoff was disregarded, an increase of correct recommendations and a decrease of incorrect recommendations was observed for all RSSs. Conclusion The RSSs vary in their ability to correctly recommend for or against FNB. An understanding of the impact of nodule size cutoffs seems necessary for the future of TIRADS.

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司