Enhanced Thrombolysis by Ultrasound-Assisted Catheter-Directed Thrombolysis and Microbubbles in an In Vitro Model of Iliofemoral Deep Vein Thrombosis

Author:

Engelberger Rolf P.12,Schroeder Verena3,Nagler Michael4,Prince Raja5,Périard Daniel1,Hayoz Daniel1,Kucher Nils6

Affiliation:

1. Division of Angiology, Cantonal Hospital Fribourg, Fribourg, Switzerland

2. Medical Faculty, University of Bern, Bern, Switzerland

3. Experimental Haemostasis Research Group, Department for BioMedical Research, University of Bern, Bern, Switzerland

4. University Institute of Clinical Chemistry, Bern University Hospital, University of Bern, Bern, Switzerland

5. University Clinic of Hematology and Hematologic Central Laboratory, Bern University Hospital, University of Bern, Bern, Switzerland

6. Clinic of Angiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland

Abstract

There is a need to improve the efficacy and safety of catheter-directed thrombolysis (CDT) for thrombo-occlusive diseases, and ultrasound-assisted CDT (USAT) is a promising approach. We tested if thrombolysis efficacy of USAT can be improved by adding gaseous microbubbles (MB). We developed an in vitro dynamic overflow model for iliofemoral deep vein thrombosis, and added MB to an USAT system with ultrasound energy and dose of tissue plasminogen activator according to clinical practice. A total of 64 clots (mean baseline weight of 8.23 ± 1.12 g, generated from citrated human whole blood from 7 healthy male volunteers) were randomly assigned to 1 of 4 study protocols of 30 minutes' duration: negative control, CDT, USAT, and USAT + MB.Thrombolysis efficacy was assessed by measuring the change in D-dimer levels in the overflow liquid and the percentage of clot weight reduction. Compared to negative control, change in D-dimer increased by 62% (p = 0.017), 128% (p = 0.002), and 177% (p < 0.001) in the CDT, USAT, and USAT + MB groups, respectively. D-dimer increase was greater in the USAT than in the CDT group (p = 0.014), and greater in the USAT + MB than in the USAT group (p = 0.033). Compared to negative control, percentage of clot weight reduction increased by 123% (p = 0.016), 154% (p = 0.002), and 233% (p < 0.001) in the CDT, USAT, and USAT + MB groups, respectively. Percentage of clot weight reduction was greatest in the USAT + MB group (p < 0.05 compared with all other groups). In conclusion, our in vitro study suggests that the thrombolytic efficacy of USAT in human whole blood clots can be improved by local administration of MB.

Publisher

Georg Thieme Verlag KG

Subject

Hematology

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3