Evaluation of a New, Rapid, Fully Automated Assay for the Measurement of ADAMTS13 Activity

Author:

Valsecchi Carla1ORCID,Mirabet Maribel2,Mancini Ilaria3ORCID,Biganzoli Marina1,Schiavone Lucia1,Faraudo Susanna4,Mane-Padros Daniel4,Giles David2,Serra-Domenech Josep2,Blanch Silvia2,Trisolini Silvia Maria5,Facchini Luca6,Rinaldi Erminia7,Peyvandi Flora13ORCID

Affiliation:

1. Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico Milano, A. Bianchi Bonomi Hemophilia and Thrombosis Center and Fondazione Luigi Villa, Milan, Italy

2. Assay Development Department, Biokit, Barcelona, Spain

3. Department of Pathophysiology and Transplantation, Università degli Studi di Milano, Milan, Italy

4. Clinical Affairs Department, Biokit, Barcelona, Spain

5. Division of Hematology, Department of Cellular Biotechnologies and Hematology, Policlinico Umberto 1, Sapienza University, Rome, Italy

6. Hematology Unit, Oncology Department, Azienda Unità Sanitaria Locale–IRCCS di Reggio Emilia, Reggio Emilia, Italy

7. Hematology Unit, A. Perrino Hospital, Brindisi, Italy

Abstract

AbstractThrombotic thrombocytopenic purpura (TTP) is a rare thrombotic microangiopathy (TMA) characterized by the severe deficiency of a disintegrin and metalloproteinase with a thrombospondin type 1 motif, member 13 (ADAMTS13) activity (< 10%). Rapid ADAMTS13 testing is crucial for an early diagnosis and optimal management of acute TTP. We evaluated the performance of the HemosIL AcuStar ADAMTS13 activity assay (Instrumentation Laboratory, Bedford, Massachusetts, United States), a fully automated chemiluminescent immunoassay with an analytical time of 33 minutes. A method comparison study was performed on 176 samples from 49 healthy donors and 127 TMA patients (109 TTP, 7 atypical hemolytic uremic syndrome, 11 other TMAs), comparing this new assay with an in-house FRETS-VWF73 assay and a commercial enzyme-linked immunosorbent assay (ELISA) (TECHNOZYM ADAMTS-13 Activity, Technoclone GmbH, Vienna, Austria). Agreement between methods was assessed with focus on ADAMTS13 activity less than 10%, the medical decision level relevant for TTP diagnosis. The HemosIL AcuStar ADAMTS13 Activity showed good correlation with both the FRETS-VWF73 (r = 0.96) and ELISA (r = 0.96) methods. Slope of the Passing–Bablok regression was 1.05 for FRETS-VWF73 and 1.02 for ELISA, and absolute bias at the medical decision level was +0.1 and +0.3%, respectively. The study also revealed high agreement with FRETS-VWF73 (kappa 0.97) and ELISA (kappa 0.98) methods in classifying TTP patients with a severe deficiency of ADAMTS13 activity. Because of its short turnaround time and full automation, the HemosIL AcuStar ADAMTS13 activity assay might become the assay of choice to rapidly test ADAMTS13 activity in plasma and thus establish the diagnosis of acute TTP in emergency settings.

Publisher

Georg Thieme Verlag KG

Subject

Hematology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3