Experimental Studies for Small Diameter Grafts in an In Vivo Sheep Model—Techniques and Pitfalls

Author:

Eghbalzadeh Kaveh1ORCID,Guschlbauer Maria2,Weber Carolyn1ORCID,Wacker Max Theodor3,Reinhardt Stefanie1,Djordjevic Ilija1ORCID,Sabashnikov Anton1,Maul Alexandra4,Sterner-Kock Anja4,Wahlers Thorsten C.W.1,Scherner Maximilian3,Wippermann Jens3

Affiliation:

1. Department of Cardiothoracic Surgery, Uniklinik Köln, Köln, Germany

2. Dezentrales Tierhaltungsnetzwerk, Universitätsklinikum Köln, Cologne, Germany

3. Department of Cardiac Surgery, Universitatsklinikum Magdeburg, Magdeburg, Germany

4. Department of Experimentelle Medizin, Universitätsklinikum Köln, Cologne, Germany

Abstract

Background Scientific attempts to create the “ideal” small diameter vascular graft have been compared with the “search of the holy grail.” Prosthetic material as expanded polytetrafluoroethylene or Dacron shows acceptable patency rates to large caliber vessels, while small diameter (< 6 mm) prosthetic conduits present unacceptably poor patency rates. Vascular tissue engineering represents a promising option to address this problem. Material and Methods Thirty-two female Texel-sheep aged 6 months to 2 years underwent surgical common carotid artery (CCA) interposition using different tissue-engineered vascular substitutes. Explantation of the grafts was performed 12 (n = 12) and 36 (n = 20) weeks after surgery. Ultrasound was performed on postoperative day 1 and thereafter every 4 weeks to evaluate the graft patency. Results The average length of implanted substitutes was 10.3 ± 2.2 cm. Anesthesia and surgical procedure could be performed without major surgical complications in all cases.The grafts showed a systolic blood flow velocity (BFV) of 28.24 ± 13.5 cm/s, a diastolic BFV of 9.25 ± 4.53 cm/s, and a mean BFV of 17.85 ± 9.25 cm/s. Native vessels did not differ relevantly in hemodynamic measurements (systolic: 29.77 cm/s; diastolic: 7.99 cm/s ±  5.35; mean 15.87 ± 10.75). There was no incidence of neurologic complications or subsequent postoperative occlusion. Perioperative morbidity was low and implantation of conduits was generally well tolerated. Conclusion This article aims to give a precise overview of in vivo experiments in sheep for the evaluation of small diameter vascular grafts performing CCA interposition, especially with regard to pitfalls and possible perioperative complications and to discuss advantages and disadvantages of this approach.

Publisher

Georg Thieme Verlag KG

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Reference48 articles.

1. Coronary artery bypass graft surgery: the past, present, and future of myocardial revascularisation;M Diodato;Surg Res Pract,2014

2. Cardiac surgery in Germany during 2014: a report on behalf of the German Society for Thoracic and Cardiovascular Surgery;A Beckmann;Thorac Cardiovasc Surg,2015

3. Critical limb ischaemia: management and outcome. Report of a national survey;Eur J Vasc Endovasc Surg,1995

4. Saphenous vein grafts: to use or not to use?;S G Raja;Heart Lung Circ,2004

5. Preoperative saphenous venography in arterial reconstructive surgery of the lower extremity;F J Veith;Surgery,1979

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3