Which Asymmetric Tibial Component Is Optimally Designed for Calipered Kinematically Aligned Total Knee Arthroplasty?

Author:

Nedopil Alexander J.1ORCID,Zamora Tomas2,Delman Connor3,Howell Stephen M.4ORCID,Hull Maury L.5ORCID

Affiliation:

1. Department of Orthopaedic Surgery, König-Ludwig-Haus, University of Würzburg, Würzburg, Germany

2. Department of Orthopaedic Surgery, Pontificia Universidad Catolica de Chile, Santiago, Chile

3. Department of Orthopaedics, University of California, Davis, Davis, California

4. Biomedical Engineering Graduate Group, University of California, Davis, Davis, California

5. Department of Mechanical Engineering, University of California, Davis, Davis, California

Abstract

AbstractCalipered kinematically aligned (KA) total knee arthroplasty (TKA) restores the patient's prearthritic joint lines and sets internal-external rotation of the tibial component parallel to the flexion-extension (FE) plane, which is not a mechanical alignment (MA) target. Two asymmetric tibial components designed for MA set the tibial component to either a femoral component (FC) target or a tibial tubercle (TT) target. The study determined the optimal asymmetric tibial component to use with KA as the one with smaller IE deviation from the MA target, greater coverage of tibial resection, and lower incidence of cortical overhang. The study included 40 patients treated with bilateral calipered KA TKA with different asymmetric tibial components in opposite knees. A best-fit of a kinematic tibial template to the tibial resection set the template's slot parallel to the knee's FE plane. Each asymmetric tibial component's anterior-posterior (AP) axis was set parallel to the slot. Computer tomography analysis determined the IE deviation (−internal/+ external) of each tibial component from its MA target, tibial resection coverage by the baseplate and insert, and incidence of cortical overhang. The patient-reported Forgotten Joint Score (FJS) and Oxford Knee Score (OKS) determined outcomes. The mean IE deviation from the MA target was 2 degrees external for the FC-target asymmetric tibial component and −8 degrees internal for the TT-target asymmetric tibial component (p < 0.001). Tibial resection coverage by the baseplate (insert) was 88% (84%) for the FC target and 84% (79%) for the TT target (p < 0.001 for baseplate and insert). The FC target insert covered 3 mm more of the posterolateral resection (p < 0.001). Posteromedial coverage was comparable. The incidence of cortical overhang was 2.5% for each baseplate. There was no difference in FJS and OKS. When performing calipered KA, the more optimal design was the asymmetric tibial component with the FC target because of the smaller deviation from its MA target and the greater coverage of the tibial resection by the baseplate and insert.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3